4 Remote control instructions for use
FAN SPEED +
FAN SPEED -
SWITCHING TO MANUAL
MODE AND AUTOMATIC MODE
NOTE:
1) During operation, the remote control must be pointed towards the stove.
2) When you are not using the remote control for a long time, remove the battery: CR2025.
5 Stove installation
• The stove must be installed on a suitable, solid, and level floor.
• The minimum diameter of a smoke duct is 80 mm, and it must be made of metal or other heat-resistant
materials and able to withstand a temperature of 220°C.
• The flue duct seal must be tight because the stove can only operate based on the pressure differential
within it and the draught in the chimney!
• Avoid deflecting the connecting pipe The horizontal pipes must be inclined by about 3 to 5°, the vertical
pipes from a height of 3 metres, in order to create an adequate differential pressure, but the total length of the
pipes must be less than 8 metres.
• The flues should only be used for this stove, they should not be shared with other devices.
• Flue pipes can only be made of heat and flame-resistant materials.
• Do not place the duct outlet in an enclosed or semi-enclosed area, such as a carport, garage, attic, low area
and narrow corridor, etc. The duct outlet must be at least 10 metres away from flammable objects.
• It is forbidden to reduce the diameter of the installation, which must be equipped with a device preventing
the return of smoke and rain.
• The stove must be correctly connected to the smoke duct by a qualified installer!
• Note: The installation of the stove must comply with local regulations and rules.
EN
TRANSMITTER
INC. POWER
RED. POWER
ON
OFF