Index Size
Acronym
269
1
C050
270
1
F024
271
1
F025
272
1
S053
274
2
S054
276
1
Hc82
277
1
AI_CfgLim-
Max_Grp3
278
1
S056
279
2
S057
281
2
S058
283
1
S059
284
2
S060
286
1
Hc00
287
1
AI_CfgLim-
Max_Grp3_Slv
288
1
Hc03
289
1
Hc04
290
1
Hc05
291
1
Hc06
292
1
Hc07
293
1
Hc08
294
1
Hc09
295
1
Hc10
296
1
Hc11
297
1
Hc14
298
1
Hc15
299
1
Hc16
μchiller +0300053FR rel. 2.4 - 09.10.2023
Min
Max
DataType
R/W
Value
Value
UINT(0..999)
R/W 15
USINT
R/W 0
USINT
R/W 0
USINT(0..2)
R/W 0
REAL
R/W 3
USINT(0..2)
R/W 1
USINT
R/W 9
UINT(20..999)
R/W 20
REAL
R/W -0.8
REAL
R/W 30
UINT(0..999)
R/W 30
REAL
R/W 0
USINT
0
4
R/W 1
USINT
R/W 11
USINT
0
2
R/W 0
USINT
0
1
R/W 0
USINT
0
1
R/W 0
USINT
0
6
R/W 1
USINT
0
6
R/W 5
USINT
0
6
R/W 4
USINT
0
5
R/W 0
USINT
0
5
R/W 0
USINT
0
5
R/W 0
USINT
R/W 1
USINT
R/W 2
USINT
R/W 0
Init
UoM
Description
Value
SECOND
C050 - Low pressure alarm run delay
F024 - Heater 1 manual mode (0=AUTO, 1=OFF, 2=ON)
F025 - Heater 2 manual mode (0=AUTO, 1=OFF, 2=ON)
S053 - Defrost synchronisation type (0=Independent, 1=Separate,
2=Simultaneous)
BAR
S054 - Delta press. to reverse the 4 way valve
Hc82 - Analogue output 2 secondary confi g. (0= Not used,
1=Source fan on/off , 2=Source fan mod)
AI_CfgLimMax_Grp3 - Lim max probe group 3
SECOND
S056 - Duration of smart start function
CELSIUS
S057 - Source frost alarm threshold
DELTAKELVIN S058 - Source frost alarm diff erential
SECOND
S059 - Source frost alarm delay time at 1K below threshold
DELTAKELVIN S060 - Source external air temperature off set
Hc00 - Analogue input 3 confi g. (0= Not used, 1= Source water
delivery temp., 2= Outside temp., 3= Discharge temp., 4=
Condensing temp., 5= Suction temp., 6= Evaporation temp., 7=
Return water temp. from user, 8= Delivery water temp. to user)
AI_CfgLimMax_Grp3 - Lim max probe group 3 secondary
Hc03 - Analogue input 6 confi g. (0= Not used, 1= Source water
delivery temp., 2= Outside temp.,3= Remote set point, 4=
Discharge temp., 5= Condensing. temp., 6= Suction temp., 7=
Evaporation temp., 8= Condensing press., 9= Evaporating press.,
10= Return water temp. from user, 11= Delivery water temp. to
user, 12= Capacity request from AIN)
Hc04 - Analogue input 7 confi g. (0= Not used, 1= Source water
delivery temp., 2= Outside temp., 3= Discharge temp., 4=
Condensing temp., 5= Suction temp., 6= Evaporation temp., 7=
Return water temp. from user, 8= Delivery water temp. to user)
Hc05 - Analogue input 6 confi g. on Secondary board (0= Not
used, 1= Source water delivery temp., 2= Outside temp., 3=
Remote set point, 4= Discharge temp., 5= Condensing. temp., 6=
Suction temp., 7= Evaporation temp., 8= Condensing press., 9=
Evaporating press., 10= Common delivery temp., 11= Delivery
water evap.2 temp., 12= Capacity request from AIN)
Hc06 - Digital input 4 confi g. (0=Not used, 1=User fl ow switch,
2=Comp.1 circ.1 overload, 3=Comp.2 circ.1 overload, 4=Remote
ON/OFF, 5=Cool/Heat, 6=2nd set point, 7=Remote alarm, 8=User
pump 1 overload, 9=LP pressure switch, 10=User pump 2 over-
load, 11=Remote cmd 1, 12=Remote cmd 2, 13=Source alarm)
Hc07 - Digital input 5 confi g. (0=Not used, 1=User fl ow switch,
2=Comp.1 circ.1 overload, 3=Comp.2 circ.1 overload, 4=Remote
ON/OFF, 5=Cool/Heat, 6=2nd set point, 7=Remote alarm, 8=User
pump 1 overload, 9=LP pressure switch, 10=User pump 2 over-
load, 11=Remote cmd 1, 12=Remote cmd 2, 13=Source alarm)
Hc08 - Digital input 6 confi g. (0=Not used, 1=User fl ow switch,
2=Comp.1 circ.1 overload, 3=Comp.2 circ.1 overload, 4=Remote
ON/OFF, 5=Cool/Heat, 6=2nd set point, 7=Remote alarm, 8=User
pump 1 overload, 9=LP pressure switch, 10=User pump 2 over-
load, 11=Remote cmd 1, 12=Remote cmd 2, 13=Source alarm)
Hc09 - Digital input 4 confi g. on Secondary board (0=Not used,
1=User fl ow switch, 2=Comp.1 circ.2 overload, 3=Comp.2 circ.2
overload, 4=Remote ON/OFF, 5=Cool/Heat, 6=2nd set point,
7=Remote alarm, 8=User pump 1 overload, 9=LP pressure switch,
10=User pump 2 overload, 11=Remote cmd 3, 12=Remote cmd
4, 13=Source alarm)
Hc10 - Digital input 5 confi g. on Secondary board (0=Not used,
1=User fl ow switch, 2=Comp.1 circ.2 overload, 3=Comp.2 circ.2
overload, 4=Remote ON/OFF, 5=Cool/Heat, 6=2nd set point,
7=Remote alarm, 8=User pump 1 overload, 9=LP pressure switch,
10=User pump 2 overload, 11=Remote cmd 3, 12=Remote cmd
4, 13=Source alarm)
Hc11 - Digital input 6 confi g. on Secondary board (0=Not used,
1=User fl ow switch, 2=Comp.1 circ.2 overload, 3=Comp.2 circ.2
overload, 4=Remote ON/OFF, 5=Cool/Heat, 6=2nd set point,
7=Remote alarm, 8=User pump 1 overload, 9=LP pressure switch,
10=User pump 2 overload, 11=Remote cmd 3, 12=Remote cmd
4, 13=Source alarm)
Hc14 - Digital input 1 confi g. (0=Not used, 1=User fl ow switch,
2=Comp.1 circ.1 overload, 3=Comp.2 circ.1 overload, 4=Remote
ON/OFF, 5=Cool/Heat, 6=2nd set point, 7=Remote alarm, 8=User
pump 1 overload, 9=LP pressure switch, 10=User pump 2 over-
load, 11=Remote cmd 1, 12=Remote cmd 2, 13=Source alarm)
Hc15 - Digital input 2 confi g. (0=Not used, 1=User fl ow switch,
2=Comp.1 circ.1 overload, 3=Comp.2 circ.1 overload, 4=Remote
ON/OFF, 5=Cool/Heat, 6=2nd set point, 7=Remote alarm, 8=User
pump 1 overload, 9=LP pressure switch, 10=User pump 2 over-
load, 11=Remote cmd 1, 12=Remote cmd 2, 13=Source alarm)
Hc16 - Digital input 1 confi g. on Secondary board (0=Not used,
1=User fl ow switch, 2=Comp.1 circ.2 overload, 3=Comp.2 circ.2
overload, 4=Remote ON/OFF, 5=Cool/Heat, 6=2nd set point,
7=Remote alarm, 8=User pump 1 overload, 9=LP pressure switch,
10=User pump 2 overload, 11=Remote cmd 3, 12=Remote cmd
4, 13=Source alarm)
FRE
99
Tableaux supervision