Index Size Acronym
75
1
A76
76
1
A77
77
1
A78
78
1
A79
79
1
A80
80
1
A81
81
1
PrevAFreeze_C1
82
1
PrevHP_C1
83
1
PrevAFreeze_C2
84
1
PrevHP_C2
92
1
Comp1Circ1_DevAlrm
93
1
Comp1Circ1_AbleToOn
94
1
Comp1Circ1_AbleToOff
95
1
Comp1Circ1_FrcdOnByT
96
1
Comp1Circ1_FrcdOff ByT
97
1
Comp2Circ1_DevAlrm
98
1
Comp2Circ1_AbleToOn
99
1
Comp2Circ1_AbleToOff
100
1
Comp2Circ1_FrcdOnByT
101
1
Comp2Circ1_FrcdOff ByT
102
1
Comp1Circ1_On
103
1
Comp2Circ1_On
104
1
Comp1Circ2_On
105
1
Comp2Circ2_On
106
1
RelayAlrm
107
1
CoolHeat
108
1
FC_Status
109
1
AFreezeHeat
110
1
SchedOnOff
111
1
A83
112
1
A84
113
1
A86
114
1
A85
115
1
Comp1Circ1_FrcOff Dev
116
1
Comp2Circ1_FrcOff Dev
117
1
Comp1Circ2_FrcOff Dev
118
1
Comp2Circ2_FrcOff Dev
119
1
A87
120
1
SrcFanCirc1_On
121
1
SrcPmp1_On
122
1
UsrPmp1_On
123
1
RevVlv_Circ1
124
1
OilEquVlv_Circ1
125
1
SrcFanCirc2_On
126
1
SrcPmp2_On
127
1
UsrPmp2_On
128
1
RevVlv_Circ2
129
1
OilEquVlv_Circ2
130
1
HeatCool
131
1
DfrRun_Circ1
132
1
DfrRun_Circ2
133
1
DfrFrcCompDfrPwr_Circ1
134
1
UnitOn
140
1
EVD_CanGo
141
1
ManPmpReqCirc1
142
1
CompsManCirc1
143
1
FrcOn_Comp1Circ1_OilMigr BOOL
144
1
FrcOn_Comp2Circ1_OilMigr BOOL
145
1
FrcOn_Comp1Circ2_OilMigr BOOL
146
1
FrcOn_Comp2Circ2_OilMigr BOOL
148
1
UsrFlw_Absent
149
1
En_DscgPPrb_Circ1
150
1
En_DscgTempPrb_Circ1
151
1
En_OvldComp1Circ1_Din
152
1
UnitCh
153
1
UnitHp
154
1
SrcFan1Circ1Status
155
1
SrcFan1Circ2Status
156
1
RegTypPrb
157
1
En_SuctPPrb_Circ1
159
1
ACU_PANEL
160
1
En_Circ2
μchiller +0300053FR rel. 2.4 - 09.10.2023
Min
Max
DataType
R/W InitValue UoM Description
Value
Value
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
TRUE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
R
FALSE
R
FALSE
R
FALSE
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
Circuit 2 BLDC - Delta pressure greater than the allowable at startup
Circuit 2 BLDC - Starting failure
Circuit 2 BLDC - Low diff erential pressure
Circuit 2 BLDC - High discharge gas temperature
Circuit 2 Inverter - Offl ine
Circuit 2 Inverter - General alarm + Error code
PrevAFreeze_C1 - Prevent request for frost condition active inside
circ.1
PrevHP_C1 - Prevent request for high pressure condition active
inside circ.1
PrevAFreeze_C2 - Prevent request for frost condition active inside
circ.2
PrevHP_C2 - Prevent request for high pressure condition active
inside circ.2
Comp1Circ1_DevAlrm - Comp.1 circ.1 in alarm condition
Comp.1 circ.1 enabled to start
Comp.1 circ.1 enabled to stop
Comp.1 circ.1 forced ON by timings (min comp. ON)
Comp1Circ1_FrcdOff ByT - Comp.1 circ.1 forced OFF by timings
(min comp. OFF)
Comp2Circ1_DevAlrm - Comp.2 circ.1 in alarm condition
Comp.2 circ.1 enabled to start
Comp.2 circ.1 enabled to stop
Comp.2 circ.1 forced ON by timings (min comp. ON)
Comp.2 circ.1 forced OFF by timings (min comp. OFF)
Comp1Circ1_On - Comp.1 circ.1 status (0=OFF 1=ON)
Comp2Circ1_On - Comp.2 circ.1 status (0=OFF, 1=ON)
Comp1Circ2_On - Comp.1 circ.2 status (0=OFF, 1=ON)
Comp2Circ2_On - Comp.2 circ.2 status (0=OFF, 1=ON)
RelayAlrm - Global alarm relay
CoolHeat - Unit in heating mode (0=Cooling, 1=Heating)
FC_Status - Free cooling valve status (0=OFF, 1=ON)
Frost heater status
Unit ON/OFF command by scheduler (0=On, 1=Off )
Unit - User delivery water temp. probe common broken or discon-
nected alarm
Circuit 2 - User delivery water temp. probe broken or disconnected
alarm
Circuit 2 - Source delivery water temp. probe broken or disconnected
alarm
Circuit 1 - Source delivery water temp. probe broken or disconnected
alarm
Comp1Circ1_FrcOff Dev - Force OFF comp.1 circ.1
Comp2Circ1_FrcOff Dev - Force OFF comp.2 circ.1
Comp1Circ2_FrcOff Dev - Force OFF comp.1 circ.2
Comp2Circ2_FrcOff Dev - Force OFF comp.2 circ.2
EVD - Incompatible HW alarm
SrcFanCirc1_On - Source fan circ.1 status (0=OFF, 1=ON)
SrcPmp1_On - Source pump 1 status (0=OFF, 1=ON)
UsrPmp1_On - User pump 1 status
RevVlv_Circ1 - Reversing valve for refr. circ.1 (0=Cooling, 1=Heat-
ing)
Oil equalisation solenoid valve circ.1
SrcFanCirc2_On - Source fan circ.2 status (0=OFF, 1=ON)
Source pump 2 on
UsrPmp2_On - User pump 2 status
RevVlv_Circ2 - Reversing valve for refr. circ.2 (0=Cooling, 1=Heat-
ing)
Oil equalisation solenoid valve circ.2
HeatCool - Unit in cooling mode (0=Heating, 1=Cooling)
Defrost is running on circ.1
Defrost is running on circ.2
Force circ.1 comp. to defrost capacity
Unit ON/OFF status (0=OFF, 1=ON)
Enable EVD EVO driver to control superheat
Request user pump activation by manual-compressor control in
circ.1
Manual status of comp. in circ.1
Force ON comp.1 circ.1 to avoid oil migration
Force ON comp.2 circ.1 to avoid oil migration
Force ON comp.1 circ.2 to avoid oil migration
Force ON comp.2 circ.1 to avoid oil migration
UsrFlw_Absent - User pump fl ow absent (0=Flow OK, 1=Flow
absent)
En_DscgTempPrb_Circ1 - Connected discharge temp. probe for
circ.1
En_DscgTempPrb_Circ1 - Connected discharge temp. probe for
circ.1
Enable comp.1 circ.1 overload input
Unit is chiller
Unit is heat pump
Source fan circ.1 status (0=OFF, 1=ON)
Source fan circ.2 status (0=OFF, 1=ON)
Control probe (0=Return; 1=Delivery)
En_SuctPPrb_Circ1 - Connected suction press. probe for circ.1
ACU panel
Enable circ.2
Tableaux supervision
FRE
105