Télécharger Imprimer la page

Carel uChiller Mode D'emploi page 106

Masquer les pouces Voir aussi pour uChiller:

Publicité

FRE
Index Size Acronym
161
1
En_Comp2Circ1
162
1
En_Comp2Circ2
163
1
En_CompsOnOff Circ1
164
1
En_CompsOnOff Circ2
165
1
En_CondTempPrb_Circ1
166
1
En_SuctTempPrb_Circ1
167
1
UsrHeater2
168
1
Al_RegulationAlrms
169
1
Al_MiscAlrms
170
1
Al_SrsCirc1
171
1
Al_SrsCirc2
172
1
Al_SrsCircs
173
1
RemCmdComp1Circ1
174
1
RemCmdComp2Circ1
175
1
RemCmdComp1Circ2
176
1
RemCmdComp2Circ2
178
1
En_RemCmdComp1Circ1_
Din
179
1
En_RemCmdComp2Circ1_
Din
180
1
En_UsrRetWTempPrb
181
1
En_UsrDlvWTempPrb
183
1
AFreezeHeatUsr_Circ2
190
1
Active2ndSetPDin
191
1
CoolHeatDin
192
1
HiP_Pstat_Circ1
193
1
OvldComp1Circ1
194
1
OvldComp2Circ1
195
1
RemAlrmDin
196
1
RemOnOff Din
198
1
UsrPmp1Ovld
199
1
UsrPmp2Ovld
200
1
UnitChOnly
197
1
UnitWW
201
1
UnitChHp
205
1
UnitHpOnly
202
1
UnitChHp_NotAA
203
1
UnitChHp_WR
206
1
Rev4WayValve_Circ2_Out-
STATUS
204
1
En_AIN_PwrReqPrb_Circ1
207
1
A88
209
1
LP_Pstat_Circ1
210
1
A90
213
1
PreventLP_Circ1
214
1
PreventLP_Circ2
106
Tableaux supervision
Min
Max
DataType
R/W InitValue UoM Description
Value
Value
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
BOOL
R
FALSE
Enable compr.2 circ.1
Enable compr.2 circ.2
Enable comp. ON/OFF for circ.1
Enable comp. ON/OFF for circ.2
Connected cond. temp. probe for circ.1
En_SuctTempPrb_Circ1 - Connected suction temp. probe for
circ.1
UsrHeater2 - User heater 2 status
Al_RegulationAlrms - Control alarms
Al_MiscAlrms - Miscellaneous alarms
Al_SrsCirc1 - Serious alarm circ.1
Al_SrsCirc2 - Serious alarm circ.2
Al_SrsCircs - Serious alarm circ.1 and circ.2
RemCmdComp1Circ1 - Remote comand comp.1 circ.1
RemCmdComp2Circ1 - Remote comand comp.2 circ.1
RemCmdComp1Circ2 - Remote comand comp.1 circ.2
RemCmdComp2Circ2 - Remote comand comp.2 circ.2
Enable remote command comp.1 circ.1 input
Enable remote command comp.2 circ.1 input
En_UsrRetWTempPrb - Connected user return water temperature
probe
En_UsrDlvWTempPrb - Connected user delivery water tempera-
ture probe
Circuit 2 user frost heater status
Second set point input
Cool/Heat input status (0=Cooling, 1=Heating)
High pressure switch on circ.1
Comp.1 circ.1 overload
Comp.2 circ.1 overload
Remote alarm
Remote unit ON/OFF command from digital input (0= OFF, 1=ON)
User pump 1 overload input logic
User pump 2 overload input logic
Unit is chiller only
Unit is WW - FALSE: Unit is not WW, TRUE: Unit is WW
Unit is Chiller/Heat pump with reversal of refrigeration cycle
Unit is heat pump only
Unit is reverse-cycle but not AA
UnitChHp_WR - WW Chiller/Heat pump with reversal on water circuit
4WayValve reverse output command for circ 2
Connected analogue capacity request probe on circuit 1
Circuit 1 - Source fan/pump alarm
Low pressure switch on circ.1
Unit - Power failure
Demande active de prévention pour basse pression active pour
le circuit 1
Demande active de prévention pour basse pression active pour
le circuit 2
μchiller +0300053FR rel. 2.4 - 09.10.2023
Tab. 7.d

Publicité

loading