Télécharger Imprimer la page

Carel uChiller Mode D'emploi page 100

Masquer les pouces Voir aussi pour uChiller:

Publicité

FRE
Index Size
Acronym
300
1
Hc17
301
1
AI_CfgLim-
Max_Grp2
302
1
He00
303
1
He01
304
1
He02
305
2
Hd04
307
2
SEtC
309
2
SEtH
311
1
AI_CfgLim-
Max_Grp1
324
2
C017
326
2
C018
328
1
E047
331
2
BMS_PwrReq
335
2
P000
337
2
P001
339
1
P002
340
1
P003
341
1
P004
342
2
P005
344
2
P006
346
2
P007
348
1
P008
349
1
P009
350
2
P010
352
1
P011
353
1
P012
354
1
P013
355
1
P014
356
1
P015
357
1
P019
358
1
P020
359
2
P021
361
1
P022
362
1
P023
363
2
P024
365
2
P025
367
2
P026
369
2
P027
371
2
P028
373
2
P029
375
2
P030
377
2
P031
379
1
P032
380
1
P033
382
2
S051
384
2
S052
386
40
Ha01
705
2
E048
707
2
E049
709
1
U079
710
1
U080
711
2
F009
713
2
F010
715
1
ID_CfgLim-
Max_Slv
716
2
F012
718
2
F013
720
2
F014
722
2
F015
724
2
F018
726
2
F019
728
2
F021
730
2
F022
732
2
S070
734
2
S071
736
2
S069
738
2
UsrDlvW-
Temp_
FromMst
100
Tableaux supervision
Min
Max
DataType
R/W
Value
Value
USINT
R/W 0
USINT
R/W 8
UINT(0..9999)
R/W 1
UINT(0..9999)
R/W 0
UINT(0..9999)
R/W 1234
STRING[4]
R/W 0
REAL
R/W 7
REAL
R/W 40
USINT
R/W 8
REAL
R/W 65
REAL
R/W 0.2
USINT(0..2)
R/W 0
REAL
REAL
R/W -25
REAL
R/W 70
UINT(0..999)
R/W 15
UINT(0..999)
R/W 120
UINT(0..999)
R/W 60
REAL
R/W 35
REAL
R/W 35
REAL
R/W 35
UINT(0..999)
R/W 15
UINT(0..999)
R/W 3
REAL
R/W 50
UINT(0..999)
R/W 30
UINT(0..999)
R/W 3
UINT(0..999)
R/W 1
UINT(0..999)
R/W 20
UINT(0..999)
R/W 20
USINT(0..101)
R/W 0
USINT(0..101)
R/W 0
REAL
R/W 0
UINT
R/W 0
UINT
R/W 0
REAL
R/W 0
REAL
R/W 0
REAL
R/W 0
REAL
R/W 45
REAL
R/W 90
REAL
R/W 30
REAL
R/W 0
REAL
R/W 0
UINT
R/W 0
UINT
R/W 0
REAL
R/W 80
REAL
R/W 40
STRING
R/W 0
REAL
R/W 1
REAL
R/W 0.2
UINT(1..15)
R/W 3
UINT(3..99)
R/W 15
REAL
R/W 14
REAL
R/W 4
USINT
R/W 0
REAL
R/W 1
REAL
R/W 0.5
REAL
R/W 3
REAL
R/W 1
REAL
R/W 40
REAL
R/W 5
REAL
R/W 0
REAL
R/W 0
REAL
R/W 0
REAL
R/W 0
REAL
R/W 0
REAL
Init
UoM
Description
Value
Hc17 - Digital input confi g. on Secondary board (0=Not used,
1=User fl ow switch, 2=Comp.1 circ.2 overload, 3=Comp.2 circ.2
overload, 4=Remote ON/OFF, 5=Cool/Heat, 6=2nd set point,
7=Remote alarm, 8=User pump 1 overload, 9=LP pressure switch,
10=User pump 2 overload, 11=Remote cmd 3, 12=Remote cmd
4, 13=Source alarm)
AI_CfgLimMax_Grp2 - Lim max probe group 2
He00 - USER profi le password
He01 - SERVICE profi le password
He02 - MANUFACTURER profi le password
Hd04 - NFC password
CELSIUS
SEtC - Cool set point
CELSIUS
SEtH - Heat set point
AI_CfgLimMax_Grp1 - Lim max probe group 1
CELSIUS
C017 - Threshold of max high pressure (HP)
BAR
C018 - Threshold of min low pressure (LP)
E047 - Type of ExV driver (0= Disabled, 1= EVD embedded, 2=EVD
EVO)
PERCENT
Capacity request using BMS net
CELSIUS
P000 - Evaporating min temp. custom envelope limit
CELSIUS
P001 - Condensing max temp. custom envelope limit
SECOND
P002 - Prevent min duration
SECOND
P003 - Out of envelope alarm delay time
SECOND
P004 - Low pressure diff erence alarm delay
RPS
P005 - Circuit destabilisation min BLDC speed threshold
PERCENT
P006 - Oil recovery min request for activation
RPS
P007 - Oil recovery min comp. speed for activation
MINUTE
P008 - Oil recovery time before activation in which the comp. can
run at min speed
MINUTE
P009 - Oil recovery duration in which the comp. speed is forced
RPS
P010 - Oil recovery comp. speed in which the comp. is forced
SECOND
P011- Oil equalisation startup time for solenoid valve on comp.
starts
SECOND
P012 - Oil equalisation solenoid valve open time
MINUTE
P013 - Oil equalisation solenoid valve min off time
MINUTE
P014 - Oil equalisation solenoid valve max off time
MINUTE
P015 - Oil equalisation max time for management
PERCENT
P019 - Compressor 1 circuit 1 manual mode (0=AUTO, 1=0%, ...
101=100%)
PERCENT
P020 - Compressor 1 circuit 2 manual mode (0=AUTO, 1=0%, ...
101=100%)
KILOPASCAL
P021 - Max permitted Delta P to start up
SECOND
P022 - Max EVD pre-opening time to equalise pressure
PERCENT
P023 - EVD pre-opening in case of pre-start to equalise pressure
RPS
P024 - Start-up speed
RPS
P025 - Max custom speed (rps)
RPS
P026 - Min custom speed (rps)
PERCENT
P027 - BLDC speed request threshold % to call on
PERCENT
P028 - BLDC speed threshold to call on fi xed speed compressor
PERCENT
P029 - BLDC speed threshold to switch off fi xed speed compres-
sor
P030 - Skip frequency: set 1 [010]
P031 - Skip frequency: band 1 [011]
P032 - Enable motor overtemperature alarm (PTC) (0=OFF, 1=ON)
[027]
P033 - Motor overtemperature alarm delay [028]
RPS
S051 - BLDC defrost speed
RPS
S052 - BLDC cycle reverse speed in defrost
New time zone to set for the controller's internal clock
DELTAKELVIN E048 - RESERVED, Delta evap. temp. (Smart opening ExV)
DELTAKELVIN E049 - RESERVED, Delta suction temp. (Smart opening ExV)
MINUTE
U079 - Burst funct. time for unit pump on
MINUTE
U080 - Burst funct. time for unit pump off
CELSIUS
F009 - Delivery air min. temp. threshold
DELTAKELVIN F010 - Delivery limit proportional band
ID_CfgLimMax_Slv - Lim digital input
DELTAKELVIN F012 - Heater off set in cool
DELTAKELVIN F013 - Heater diff erential in cool
DELTAKELVIN F014 - Heater off set in heat
DELTAKELVIN F015 - Heater diff erential in heat
CELSIUS
F018 - Hot-Start set point
DELTAKELVIN F019 - Hot-Keep diff erential
DELTAKELVIN F021 - Common delivery user water temp. probe off set
DELTAKELVIN F022 - Evap.2 frost temp. probe off set
DELTAKELVIN S070 - Cond.1 frost temp. probe off set
DELTAKELVIN S071 - Cond.2 frost temp. probe off set
CELSIUS
S069 - Temperature set point for fan-defrost function
(0=Function disabled)
CELSIUS
Delivery water temperature to user received from Main
(Single evaporator)
μchiller +0300053FR rel. 2.4 - 09.10.2023