28 INSTALLATION
the system checked immediately, as
performance will be poor.
5
End of cycle.
• At the end of the test cycle, a message will
display. The test cycle will end and the
appliance will shut off automatically after a
short delay.
Check the Duct Condition
TM
If the Flow Sense
LED is turned on, check the
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
• When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the results during the
two tests may not be the same.
• Do not interrupt the test cycle, as this could
result in inaccurate results.
• Even if the LED doesn't light up during the test
cycle, some restrictions may still be present in
the exhaust system. Refer to the Venting the
Dryer section of this manual for complete
exhaust system and venting requirements.
Error Messages
Check the error message before you call for
service.
Error Message
Possible Cause & Solution
Temp sensor
Temperature sensor failure.
error 1
• Turn off the appliance and
Humidity sensor
Humidity sensor failure.
error
• Turn off the appliance and
call for service.
call for service.
Error Message
Possible Cause & Solution
High voltage
Electric dryer power cord is
Low voltage
not connected correctly, or
Power supply
house power supply is
incorrect.
• Reset circuit breaker or
House fuse is blown, circuit
breaker has tripped, or
power outage has occurred.
• If the problem is a circuit
Gas supply
Gas supply or service turned
off. (gas model only.)
• Confirm that house gas
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
Check for blockages and lint buildup.
replace fuse. Do not
increase the fuse capacity.
overload, have it corrected
by a qualified electrician.
shutoff and the dryer gas
shutoff are both fully
open.
Too many elbows or
exhaust too long