Télécharger Imprimer la page

LG DL X860 E Serie Manuel D'utilisation page 23

Publicité

Les langues disponibles

Les langues disponibles

Correct Venting
Incorrect Venting
Connecting Gas Dryers
WARNING
• To reduce the risk of fire or explosion, electric
shock, property damage, injury to persons, or
death when using this appliance, follow
requirements including the following.
Electrical Requirements for Gas
Models
WARNING
• This dryer is equipped with a three-prong
grounding plug for protection against shock
hazard which should be plugged directly into a
properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from
this plug.
• Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
• For personal safety, this dryer must be properly
grounded.
• This dryer must be plugged into a 120-VAC, 60-
Hz. grounded outlet protected by a 15-ampere
fuse or circuit breaker.
• Where a standard 2-prong wall outlet is
encountered, it is your personal responsibility
and obligation to have it replaced with a
properly grounded 3-prong wall outlet.
Gas Supply Requirements
WARNING
• DO NOT attempt any disassembly of the dryer;
disassembly requires the attention and tools of
an authorized and qualified service technician or
company.
• DO NOT use an open flame to inspect for gas
leaks. Use a noncorrosive leak detection fluid.
• Gas pressure must not exceed 10.5-inch (26.7
cm) water column for NG, or 13-inch (33.1 cm)
water column for LP.
• Isolate the dryer from the gas supply system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply at
pressures greater than 3.5 kPa.
• Supply line requirements: Your laundry room
must have a rigid gas supply line to your dryer.
In the United States, an individual manual
shutoff valve MUST be installed within at least 6
ft. (1.8 m) of the dryer, in accordance with the
National Fuel Gas Code ANSI Z223.1 or Canadian
gas installation code CSA B149.1. A 1/8-inch NPT
pipe plug must be installed.
• If using a rigid pipe, the rigid pipe should be 0.5-
inch IPS. If acceptable under local codes and
ordinances and when acceptable to your gas
supplier, 3/8-inch approved tubing may be used
where lengths are less than 20 ft. (6.1 m). Larger
tubing should be used for lengths in excess of 20
ft. (6.1 m).
• To prevent contamination of the gas valve,
purge the gas supply of air and sediment before
connecting the gas supply to the dryer. Before
tightening the connection between the gas
supply and the dryer, purge remaining air until
the odor of gas is detected.
• Use only a new AGA- or CSA-certified gas supply
line (in compliance with the Standard for
Connectors for Gas Appliances, ANSI Z21.24 •
CSA 6.10) with flexible stainless steel connectors.
• Use Teflon tape or a pipe-joint compound that is
insoluble in propane (LP) gas on all pipe threads.
Connecting the Gas Supply
NOTE
• In the Commonwealth of Massachusetts: This
product must be installed by a licensed plumber
or gas fitter. When using ball-type gas shut off
valves, they must be T-handle-type. A flexible gas
connector, when used, must not exceed 3 feet.
INSTALLATION
23

Publicité

loading