• The appliance has its own terminal block that
must be connected to a separate 230 VAC, 60-
Hertz, single-phase circuit, fused at 30 amperes.
(The circuit must be fused on both sides of the
line.) ELECTRICAL SERVICE FOR THE APPLIANCE
SHOULD BE OF THE MAXIMUM RATE VOLTAGE
LISTED ON THE NAMEPLATE. DO NOT CONNECT
THE APPLIANCE TO 110-, 115-, OR 120-VOLT
CIRCUIT.
• If the branch circuit to appliance is 15 ft. (4.5 m)
or less in length, use UL (Underwriters
Laboratories) listed No.-10 AWG wire (copper
wire only), or as required by local codes. If over
15 ft. (4.5 m), use UL-listed No.-8 AWG wire
(copper wire only), or as required by local codes.
Allow sufficient slack in wiring so the appliance
can be moved from its normal location when
necessary.
• The power cord (pigtail) connection between the
wall receptacle and the appliance terminal block
IS NOT supplied with the appliance. Type of
pigtail and gauge of wire must conform to local
codes and with instructions on the following
pages.
• Do not modify the plug and internal wire
provided with the appliance.
• The appliance should be connected to a 4-hole
outlet.
• If the plug does not fit the outlet, a proper outlet
will need to be installed by a qualified electrician.
• Connect the power cord to the terminal block.
Each colored wire should be connected to the
same color screw. Wire color indicated in manual
is connected to the same color screw in the
block.
• Grounding through the neutral conductor is
prohibited for: (1) new branch-circuit
installations and (2) areas where local codes
prohibit grounding through the neutral
conductor.
• This appliance is supplied with the neutral wire
grounded. This white ground wire MUST BE
MOVED to the neutral terminal when a 4-wire
cord is to be used, or where grounding through
the neutral conductor is prohibited.
Connecting the Water Inlet
Hose
To generate steam, the dryer must be connected
to the cold water tap using a new water supply
hose. Do not use old hoses.
WARNING
• Do not overtighten the hoses or cross-thread the
hose fittings. Overtightening or cross-threading
can damage the valves or couplings, resulting in
leaking and property damage.
• Do not reuse old hoses. Use only new hoses
when installing the appliance. Old hoses could
leak or burst causing flooding and property
damage. Contact an LG Customer Information
Center for assistance in buying hoses.
CAUTION
• Periodically check the hoses for cracks, leaks,
and wear, and replace the hoses every five years.
• Do not stretch the water hoses intentionally, and
make sure that they are not pinched, crushed or
kinked by other objects.
• Water supply pressure must be between 20 psi
and 120 psi (138 - 827 kPa). If the water supply
pressure is more than 120 psi, a pressure
reducing valve must be installed.
• Do not store or install the appliance in a location
subject to freezing temperatures. Damage to the
water inlet hoses and internal mechanisms of
the appliance can result. If the appliance was
exposed to freezing temperatures prior to
installation, allow it to stand at room
temperature for several hours before use and
check for leaks prior to operation.
• Do not use flood-preventing hoses with auto
shut off devices. The devices can be tripped
during fill and prevent the appliance from filling
properly.
How to Connect the Water Inlet
Hoses
1
Check the fittings and seals. Inspect the
threaded fitting on each hose and make sure
there is a rubber seal
of each hose to prevent leaking.
INSTALLATION