6 Technical information / Functioning / Parameters
Menu items / Adjustable parameters
(when connected to programming unit)
Switch-on point 1 / 2
Upper limit value at which the output changes its switching status.
• Setting range: 1 ... 100% of the value of the
measuring range,
• indicated in the set unit (bar, PSI, kPa).
Switch-off point 1 / 2
Lower limit value at which the output changes its switching status.
• Setting range: 0.5 ... 99.5% of the value of the
measuring range,
• indicated in the set unit (bar, PSI, kPa).
rPx is always lower than SPx. The unit does not accept values for
rPx which are higher than SPx.
Changing the switch-on point also changes the switch-off point
(the distance between SPx and rPx remains constant).
If the distance is higher than the new switch point, it is automati-
cally reduced (rPx is set to the minimum setting value).
Configuration of pin 4 (output 1 / communication interface)
5 settings can be selected:
- Hno = hysteresis / normally open
- Hnc = hysteresis / normally closed
- Fno = window function / normally open
- Fnc = window function / normally closed
- EPS = The sensor transfers its data to the programming and
Configuration of pin 2 (output 2 / Teach input)
5 settings can be selected:
- Hno = hysteresis / normally open
- Hnc = hysteresis / normally closed
- Fno = window function / normally open
- Fnc = window function / normally closed
- tch = pin 2 is the input for the Teach signal; the settings for
For the functioning of the connector pins 2 and 4 → page 31
28
display unit via pin 4; the settings for SP1 and rP1 are
not effective.
SP2 and rP2 are not effective.