DUCTED VERSION
Vent Connector Installation
NOTE
Remove protective film entirely.
NOTE
Removal of the charcoal filter is required for
this version. See section "Range Hood Care".
Install 7" (17.8 cm) round vent mounting plate.
Attach to range hood using the indicated screws
provided in hardware kit.
A
NOTE
The 7" (17.8 cm) round vent mounting plate
can be installed up to 1" (2.5 cm) on either
side of the hood center to accommodate
off center ductwork.
Power Supply Cable Installation
1. For direct wire installations, run the home
power supply cable according to the National
Electric Code or CSA standards and local
codes and ordinances.
There must be enough wiring from the fused
disconnect (or circuit breaker) box to make the
connection in the hood electrical terminal box.
NOTE
Do not reconnect power until the
installation is complete.
2. Remove the screw from the
terminal box cover.
Remove terminal box
cover and set aside.
A. T erminal box cover
B. Screw
A. .29 x .65 cm screws
B
B. 7" (17.8 cm) round vent
mounting plate.
C. Round vent knockout
C
INSTALL RANGE HOOD
3. Remove the power supply knockout from the
top or rear of the vent hood (depending on the
incoming location of your home power supply
cable) and install a UL listed or CSA approved
½" strain relief.
A
A. Power supply
knockout
4. Using 2 or more people. lift the hood into final
position. Tighten the strain relief screws.
5. Position the range hood so that the large end
of the keyhole slots are over the mounting
screws. Then push the hood toward the wall
so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the
screws are in the narrow neck of slots.
6. Connect vent duct work to hood. Seal joints
with vent clamps or duct tape to make secure
and airtight.
7. Check that back draft dampers work properly.
MAKE ELECTRICAL CONNECTION
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect power.
G
C
D
A
B
2. Use UL listed wire connectors and connect
white wires (A) together. (there are two white
wires on the hood, both must be connected
to the power supply).
3. Use UL listed wire connectors and connect
black wires (B) together.
A
4. Connect green (or bare) ground wire from
B
power supply to green ground screw in
terminal box and securely tighten.
5. Install terminal box cover and reconnect power.
A.White wires
B. Black wires
C. UL listed wire connector
E
D. Green (or bare) ground
wire
E. Home power supply cable
F. UL listed or CSA approved
½" strain relief
F
G. Green ground screw
11