Télécharger Imprimer la page

schmalz SCTMi IOL Notice D'utilisation page 69

Publicité

CONFIDENTIAL
#
Configuration
1...16
Read Valvetype for ejektors #1 - #16
565
0x0235
Write Valvetype for ejektors #1 - #16 (only valid
1...16
566
0x0236
after system command 170 is written)
1...16
Read Nozzletype for ejektors #1 - #16
567
0x0237
Write Nozzletype for ejektors #1 - #16 (only
1...16
568
0x0238
valid after system command 170 is written)
Process Settings
1...16
100
0x0064
Switchpoint 1 (SP1) for ejectors #1 - #16
1...16
Resetpoint 1 (rP1) for ejectors #1 - #16
101
0x0065
1...16
102
0x0066
Switchpoint 2 (SP2) for ejectors #1 - #16
1...16
Resetpoint 2 (rP2) for ejectors #1 - #16
103
0x0067
1...16
106
0x006A
Duration automatic blow for ejectors #1 - #16
Permissable evacuation time for ejectors #1 -
1...16
107
0x006B
#16
1...16
Permissable leakage rate for ejectors #1 - #16
108
0x006C
1...16
109
0x006D
Control-mode for ejectors #1 - #16
Observation
Monitoring
Process data in copy
40
0x0028
0
Process data out copy
41
0x0029
0
1...16
64
0x0040
Vacuum for ejectors #1 - #16
Input pressure live
1
Input pressure min
65
0x0041
2
3
Input pressure max
Primary supply voltage live
1
Primary supply voltage min
66
0x0042
2
3
Primary supply voltage max
Auxiliary supply voltage live
1
Auxiliary supply voltage min
67
0x0043
2
Auxiliary supply voltage max
3
Diagnosis
Device Status
Error count
32
0x0020
0
Device status
36
0x0024
0
Detailed device status
37
0x0025
0
130
0x0082
0
Active errors
1
Extended Device Status - Type
138
0x008A
Extended Device Status - ID
2
NFC status
139
0x008B
0
Condition Monitoring [CM]
1...17
Condition monitoring
146
0x0092
Counters
1...16
Vacuum on counter for ejectors #1 - #16
140
0x008C
1...16
Valve operating counter for ejectors #1 - #16
141
0x008D
1...16
Vacuum on counter for ejectors #1 - #16
143
0x008F
1...16
Valve operating counter for ejectors #1 - #16
144
0x0090
16x1
bytes
0,1,3,255
ro
0,1,3, 254,
16x1
bytes
rw
255
16x1
bytes
0-5, 255
ro
0-5, 254,
16x1
bytes
rw
255
999 > SP1
16x2
bytes
rw
> rP1
SP1 > rP1
16x2
bytes
rw
> SP2
rP1 > SP2
16x2
bytes
rw
> rP2
SP2 > rP2
16x2
bytes
rw
>= 10
16x2
bytes
10-9999
rw
16x2
bytes
0-9999
rw
16x2
bytes
10-999
rw
16x1
bytes
0-5
rw
see Pd in
-
ro
see Pd out
-
ro
16x2
bytes
-
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
ro
2
bytes
-
ro
2
bytes
ro
2
bytes
-
ro
1
byte
-
ro
96
bytes
-
ro
17
bytes
-
ro
1
byte
ro
-
2
bytes
ro
1
byte
-
ro
17x2
bytes
-
ro
16x4
bytes
-
ro
16x4
bytes
-
ro
16x4
bytes
-
ro
16x4
bytes
-
ro
0 = NC,
1 = NO,
-
3 = IMP,
255 = not connected
Subindex corresponds to ejector number
0 = NC,
1 = NO,
-
3 = IMP,
254 = not written,
255 = not connected
0 = EV,
1 = 03,
2 = 05,
3 = 07,
-
4 = 10,
5 = 12,
255 = not connected
Subindex corresponds to ejector number
0 = EV,
1 = 03,
2 = 05,
3 = 07,
-
4 = 10,
5 = 12,
254 = not written,
255 = not connected
750
Unit: 1mbar, Subindex corresponds to ejector number
600
Unit: 1mbar, Subindex corresponds to ejector number
550
Unit: 1mbar, Subindex corresponds to ejector number
540
Unit: 1mbar, Subindex corresponds to ejector number
200
Unit: 1ms, Subindex corresponds to ejector number
2000
Unit: 1ms, Subindex corresponds to ejector number
250
Unit: 1mbar/s, Subindex corresponds to ejector number
Control mode settings for each ejector
Subindex corresponds to ejector number
subindex 0 for access to full array (16 bytes)
0x00 = control is not active, SP1 in hysteresis mode
2
0x01 = control is not active, SP1 in comparator mode
0x02 = control is active
0x03 = control is active with supervision of leakage
0x04 = control is active, continuous succing disabled
0x05 = control is active with supervision of leakage, continuous succing disabled
-
see PD in
-
see PD out
-
Unit: 1mbar, Subindex corresponds to ejector number
Unit: 1mbar
-
Unit: 1mbar
Unit: 1mbar
Unit: 0.1V
-
Unit: 0.1V
Unit: 0.1V
Unit: 0.1V
-
Unit: 0.1V
Unit: 0.1V
-
Number of errors since last power-up
0 = Device is operating properly
1 = Maintenance required
-
2 = Out of Spec
3 = unused
4 = Failure
Information about currently pending events (Event-List)
Byte 0 = Type of Event 1
Byte 1...2 = ID of Event 1
-
Byte 3 = Type of Event 2
Byte 4...5 = ID of Event 2 etc.
Byte 0 bis Byte 15 (Subindex 1-16):
For each ejector
Bit 0 = Measurement range overrun
Bit 1 = Vacuum calibration failed
Bit 2 = Configuration Error
Byte 16 (Subindex 17):
Control-Unit:
-
Bit 0: Internal error: data corruption
Bit 1: Configuration Error
Bit 2: Primary voltage too low
Bit 3: Primary voltage too high
Bit 4: Secondary voltage too low
Bit 5: Secondary voltage too high
Bit 6: Supply pressure too low or too high
Bit 7: reserved
Extended Device Status - Type (see below) 0x10: Device operation properly
-
Event Code of current device status (see table below)
Result of recent NFC activity:
0x00: Data valid, write finished successfully
0x23: Write failed: Write access locked
0x30: Write failed: parameter(s) out of range
0x31: Write failed: parameter value too high
0x32: Write failed: parameter value too low
-
0x41: Write failed: parameter set inconsistent
0xA1: Write failed :invalid authorisation
0xA2: NFC not available
0xA3: Write failed: invalid data structure
0xA5: Write pending
0xA6: NFC internal error
Subindex 1...16:
for each ejector:
Bit 0: valve protection active
Bit 1: Evacuation time greater than limit
Bit 2: Leakage rate greater than limit
Bit 3: SP1 not reached in suction cycle
Bit 4: Free flow vacuum too high
-
Bit 5-15: reserved
Subindex 17:
for Control-Unit:
Bit 0: Primary Voltage limit
Bit 1: Secondary voltage limit
Bit 2: Input pressure limit
Counter for Vacuum on (non-erasable, saved every 256 cycles)
-
Subindex corresponds to ejector number
Counter for valve operating (non-erasable, saved every 256 cycles)
-
Subindex corresponds to ejector number
Counter for Vacuum on (erasable, saved every 256 cycles)
-
Subindex corresponds to ejector number
Counter for valve operating (erasable, saved every 256 cycles)
-
Subindex corresponds to ejector number

Publicité

loading

Ce manuel est également adapté pour:

Sctmi iol e4 aby00002eSctmi iol e8 aby00003d