CONFIDENTIAL
#
Process data Out
PD out byte 0
Input Pressure
PD out byte 1
Device Select
Vacuum Ejector #1
Blow-off Ejector #1
Vacuum Ejector #2
Blow-off Ejector #2
PD out byte 2
Vacuum Ejector #3
Blow-off Ejector #3
Vacuum Ejector #4
Blow-off Ejector #4
Vacuum Ejector #5
Blow-off Ejector #5
Vacuum Ejector #6
Blow-off Ejector #6
PD out byte 3
Vacuum Ejector #7
Blow-off Ejector #7
Vacuum Ejector #8
Blow-off Ejector #8
Vacuum Ejector #9
Blow-off Ejector #9
Vacuum Ejector #10
Blow-off Ejector #10
PD out byte 4
Vacuum Ejector #11
Blow-off Ejector #11
Vacuum Ejector #12
Blow-off Ejector #12
Vacuum Ejector #13
Blow-off Ejector #13
Vacuum Ejector #14
Blow-off Ejector #14
PD out byte 5
Vacuum Ejector #15
Blow-off Ejector #15
Vacuum Ejector #16
Blow-off Ejector #16
ISDU Parameters
ISDU Index
Subindex
Parameter
dec
hex
dec
Identification
Device Management
Vendor name
16
0x0010
0
Vendor text
17
0x0011
0
Product name
18
0x0012
0
Product ID
19
0x0013
0
Product text
20
0x0014
0
Serial number
21
0x0015
0
Hardware revision
22
0x0016
0
Firmware revision
23
0x0017
0
Article number
250
0x00FA
0
Production date
252
0x00FC
0
Product text (detailed)
254
0x00FE
0
354
0x0162
0
Product configuration (detailed)
Device Localization
Application specific tag
24
0x0018
0
Function tag
25
0x0019
0
Location tag
26
0x001A
0
Equipment identification
242
0x00F2
0
Geolocation
246
0x00F6
0
NFC web link
248
0x00F8
0
Storage location
249
0x00F9
0
Installation date
253
0x00FD
0
Parameter
Device Settings
Commands
System command
2
0x0002
0
Access Control
Extended device access locks
90
0x005A
0
Pin-Code NFC
91
0x005B
0
Initial Settings
1...16
Blow mode for ejektors #1 - #16
110
0x006E
Bits
Access
7...0
wo
7...0
wo
7...0
wo
7...0
wo
7...0
wo
7...0
wo
Value
Size
Access
Range
0...32 bytes
-
ro
0...32 bytes
-
ro
0...32 bytes
-
ro
0...32 bytes
-
ro
0...32 bytes
-
ro
9
bytes
-
ro
2
bytes
-
ro
4
bytes
-
ro
14
bytes
-
ro
3
bytes
-
ro
1...64 bytes
-
ro
1...67 bytes
-
ro
1...32 bytes
-
rw
1...32 bytes
-
rw
1...32 bytes
-
rw
1...64 bytes
-
rw
1...64 bytes
-
rw
http://...
1...64 bytes
rw
https://...
1...32 bytes
-
rw
1...16 bytes
-
rw
129, 131,
165, 167,
1
byte
wo
168, 170,
171
1
byte
0-255
rw
2
bytes
0-999
rw
16x1
bytes
0-2
rw
Remark
Input Pressure
Device Select
Device selected 0 = Control-Unit
Device selected 1-16 = Ejector 1 - 16
Suction Control
Blow-off Control
Suction Control
Blow-off Control
Suction Control
Blow-off Control
Suction Control
Suction Control
Blow-off Control
NC ejectors
Suction Control
Suction on: 1
Blow-off Control
Suction off: 0
Suction Control
Blow-off Control
NO ejectors
Suction Control
Suction on: 0
Blow-off Control
Suction off: 1
Suction Control
Blow-off Control
IMP ejectors
Suction Control
Suction on: 0 -> 1 (Transition)
Blow-off Control
Suction off: Blow-off active
Suction Control
Blow-off Control
Suction Control
Blow-off Control (externally controlled blow off)
Blow-off Control
Suction Control
Blow-off active: 1
Blow-off Control
Blow-off inactive: 0
Suction Control
Blow-off Control
Hint: While blow-off is active, suction is always disabled
Suction Control
Blow-off Control
Suction Control
Blow-off Control
Suction Control
Blow-off Control
Default Value
J. Schmalz GmbH
Manufacturer designation
Innovative Vacuum Solutions
Vendor text
-
Product name
-
Product variant name, e.g.: SCTMi
-
Order-code, e.g.: SCTMi
-
Serial number, e.g.: 999000101
-
Hardware revision, e.g.: 00
-
Firmware revision, e.g.: S1.01A1.01
-
Order-number, e.g.: 10.03.01.00500
-
Date code of production (month and year, month is letter coded, e.g.: I19
-
Detailed type description of the device
-
Detailed description of the device
***
User string to store location or tooling information
***
User string to store location or tooling information
***
User string to store location or tooling information
***
User string to store identification name from schematic
***
User string to store geolocation from handheld device
https://myproduct.schmalz.com/#/
Web link to NFC app (base URL for NFC tag)
***
User string to store storage location
***
User string to store date of installation
0x81 (dec 129): Reset application
0x83 (dec 131): Back to box (valve and nozzle type excluded - manual restart required)
0xA5 (dec 165): Calibrate vacuum sensor
0xA7 (dec 167): Reset erasable counters
-
0xA8 (dec 168): Reset voltages min/max
0xAA (dec 170): Write configuration (valve and nozzle type - manual restart required)
0xAB (dec 171): Reset configuration to factory defaults (valve and nozzle type - manual restart
required)
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: Not used
0
Bit 3: Not used
Bit 4: IO-Link event lock (suppress sending IO-Link events)
Bit 5-7: Not used
0
Pin-Code for NFC write
Blow mode setting for each ejector
subindex corresponds to ejector number
0
0x00 = Externally controlled blow-off
0x01 = Internally controlled blow-off – time-dependent
0x02 = Externally controlled blow-off – time-dependent
Remark