4.0 Alarms

rEr
The value of the measured mV is out of the alarm window. There are 2 possibilities:
1) the mV value is too low:
-
the tank of the chemical is empty
-
verify the state of the injection valve « g »
-
verify the state of the hoses of the pump
2) the mV value is too high:
-
verify the presence of siphon effect (verify the state of the hoses of the pump)
-
verify that the injection valve is well positioned (check the diagram on page 14)
-
verify that no chemical has been hadded by hand in the swimming pool
cEr
The calibration cannot be done for different reasons:
-The buffer solution is not good (replace it with a new one)
-The Rx probe doesn't work (replace it with a new one)
-The probe's quality is lower than 25 % (replace it with a new one)
ULo
The tank of the chemical is empty (option)

4.1 Diagram

5.0 Maintenance

ATTENTION!
It's necessary to effectuate all the operations with the power off and with gloves and glasses suitable for the product
used. Consult the supplier of the chemical product.