USE AND MAINTENANCE MANUAL
PROBLEM
1) THE ELECTROPUMP DOES
NOT PUMP WATER, THE MOTOR
DOES NOT RUN
2) THE MOTOR RUNS BUT THE
ELECTROPUMP DOES NOT
PUMP LIQUID
3) THE ELECTROPUMP STOPS
AFTER RUNNING FOR A PERIOD
OF TIME BECAUSE ONE OF
THE THERMAL MOTOR CIRCUIT
BREAKER TRIPS
4) THE ELECTROPUMP DOES
NOT REACH THE DESIRED
PRESSURE
5) L'ELETTROPOMPA NON
RAGGIUNGE LA PRESSIONE
DESIDERATA
6) THE ELECTROPUMP DOES
NOT RUN IN CONTINUOUS
MODE
If the problem persists despite the recommended corrective actions, contact the Customer Assistance Service.
16
POSSIBLE CAUSE
1) No power.
2) Motor protection tripped.
3) Defective condenser.
4) Shaft blocked.
5) Pressure switch installed
incorrectly or damaged.
1) Empty pump body.
2) Air inlet from the suction
pipe.
3) Suction height above the
height recommended for
the unit.
1) The power supply does not
comply with the data on the
nameplate.
2) A solid object is blocking
the
impellers.
3) The liquid is too thick.
4) The liquid or the
environment are too hot.
1) The tank membrane is
damaged.
2) No compressed air in the
tank.
3) The foot valve on the
suction pipe is blocked and
not appropriately sealed.
1) The pressure required to
stop the pump pre-set on the
pressure switch is too low.
2) Air inlet from the suction
pipe.
1) The maximum adjustment
of the pressure switch is
too high.
2) Air inlet from the suction
pipe
REMEDY
1) Verify that voltage is present and that the plug has been
correctly inserted.
2) Determine the cause of the problem and reset the switch. If the
thermal switch has been enabled, wait for the system to cool down.
3) Contact the Customer Assistance Service.
4) Verify the cause and unblock the electropump.
5) Contact the Customer Assistance Service.
1) Stop the pump and fill the body with water using the filling cap
(fig. 1, n. 9).
2) Verify that: a) the joints are sealed - b) the fluid level has not
lowered below the foot valve - c) the foot valve is sealed and
not blocked - d) there are no siphons, bends, counter-slopes or
throats along the suction pipes.
3) Check and reduce the suction height or use a device with more
suitable characteristics.
1) Check the voltage on the power supply cable leads
2) Disassemble and clean the electropump.
3) Dilute the pumped fluid.
4) Remove the cause of the problem, wait for the pump to cool
down and restart it.
1) Have the membrane or tank replaced by qualified personnel.
2) Fill the tank with air using the delivery valve and a maximum
pressure of 1.5 bar.
3) Disassemble and clean the valve or replace it when necessary.
1) Contact the Customer Assistance Service.
2) See point 2.2.
1) Contact the Customer Assistance Service.
2) See point 2.2.!! Warning: fluid overheating hazard and danger
of burns!