Télécharger Imprimer la page
Empire Heating Systems DV-55SPP Instructions D'installation Et Manuel Du Propriétaire
Empire Heating Systems DV-55SPP Instructions D'installation Et Manuel Du Propriétaire

Empire Heating Systems DV-55SPP Instructions D'installation Et Manuel Du Propriétaire

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
state or local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
AND
FAN TYPE
DIRECT VENT
WALL FURNACE
MODEL
DV-55SPP
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Page 1

Publicité

loading

Sommaire des Matières pour Empire Heating Systems DV-55SPP

  • Page 1 OWNER'S MANUAL FAN TYPE DIRECT VENT WALL FURNACE MODEL DV-55SPP Installer: Leave this manual with the appli- ance. WARNING: If the information in these instruc- Consumer: Retain this manual for future refer- tions are not followed exactly, a fire or explosion ence.
  • Page 2 TABLE OF CONTENTS SECTION PAGE Important Safety Information ........................3 Safety Information for Users of LP Gas ......................4 Requirements for Massachusetts ........................5 Introduction ..............................6 Specifications ...............................6 Gas Supply ............................... 7-8 Clearances ..............................8 Installation Instructions .......................... 9-11 Lighting Instructions ..........................12 Pilot Flame Characteristics ........................13 Main Burner Flame Characteristics ......................13 Wiring ................................14 Service and Maintenance Suggestions .......................15...
  • Page 3 IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPeRaTe THIS aPPLIaNCe WITHOUT FRONT PaNeL INSTaLLeD. Due to high temperatures the appliance should be located is imperative that control compartments, burners and • out of traffic and away from furniture and draperies. circulating air passageways of the appliance be kept clean.
  • Page 4 SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone's safety will depend colorless.
  • Page 5 REqUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate shall be installed in every dwelling, building or structure used in permanently mounted to the exterior of the building at a whole or in part for residential purposes, including those minimum height of eight (8) feet above grade directly in owned or operated by the Commonwealth and where the...
  • Page 6 Installation in Residential Garages match be used. The match will light the pilot faster than the piezo Gas utilization equipment in residential garages shall be installed under this condition. SPECIFICATIONS Model DV-55SPP Input BTU/HR 55,000 Height 82 3/8" Width 16"...
  • Page 7 GAS SUPPLY a manual main gas cock should be located in the vicinity of Locating Gas Supply the unit. Where none exists, or where its size or location is not The gas line can enter the unit either through the floor or outside adequate, contact your local authorized installer for installation wall.
  • Page 8 Checking Manifold Pressure Both Propane and Natural gas valves have a built-in pressure regu- lator in the gas valve. Natural gas models will have a manifold pressure of approximately 4.0" w.c. at the valve outlet with the inlet pressure to the valve from a minimum of 6.0" w.c. for the purpose of input adjustment to a maximum of 7.0"...
  • Page 9 INSTALLATION INSTRUCTIONS Locating Wall Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
  • Page 10 INSTALLATION INSTRUCTIONS (continued) Cutting Vent Tubes This is the most important part of the installation. With the furnace installed on wall the 6" diameter air inlet tube and the 4" diam- eter flue outlet tube are to be marked and cut using the following procedure.
  • Page 11 INSTALLATION INSTRUCTIONS (continued) Apply furnace cement to 4" diameter flue outlet collar on Warning: When vinyl siding vent kit, DV-822 or 2" x 4" combustion chamber and to 4" diameter collar on vent cap. framing is added to an existing installation (furnace is Attach 4"...
  • Page 12 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by •...
  • Page 13 PILOT FLAME CHARACTERISTICS PROPER FLAME ADJUSTMENT The correct pilot flame (Figure 11) will be blue, extending past the thermocouple. The flame will surround the thermocouple just below the tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5"...
  • Page 14 WIRING Wiring The appliance, when installed, must be electrically grounded in ac- cordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 15 SERVICE & MAINTENANCE SUGGESTIONS Replacing Fan and Oiling the Motor If Electrode Does Not Produce Spark: The fan motor should be cleaned and oiled once each heating season. Check wire connections. Check gap for pilot burner to the electrode tip. Should be To reach the motor, withdraw the metal shroud surrounding the fan between 1/8"...
  • Page 16 PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Index Part No. Description Index Part No. Description 11762 Outer Casing Top DV-781 Lighting Hole Cover w/Mica 632024 Motor Mount (Four Required) DV-064 Cover Plate for Observation Hole 11764...
  • Page 17 PARTS VIEW 12431-12-1109 Page 17...
  • Page 18 MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local empire dealer. See the dealer locator at www.empirecomfort.com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 19 SERVICE NOTES 12431-12-1109 Page 19...
  • Page 20 empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com Page 20 12431-12-1109...
  • Page 21 à CIRCULATION FORCéE AvEC UN évENT DIRECT MODèLES Dv-55SPP AvERTISSEMENT: Assurez vous de bien suivre les instructions données dans cette notice Installateur: L a i s s e z c e t t e n o t i c e a v e c pour réduire au minimum le risque d’incendie...
  • Page 22 Informations Générales Spécifications Ce radiateur est un modèle conformément certifié avec l'American National Modèle DV-55SPP Standard / CSA Standard Z21.86 et CSA 2.32 par Canadian Standards Puissance BTU/H (KW/H) 55,000 (161.12) Association comme étant un radiateur mural à circulation forcée avec un Hauteur 82 3/8"...
  • Page 23 INFORMATION DE SéCURITé POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et des famille. Un jour, lorsqu’il n’y aura pas une minute à perdre, la explosions. Dans son état naturel, le propane est inodore et sans sécurité...
  • Page 24 d’un malfonctionnement du régulateur, la distance de 6' DV-822 L’assemblage d’évent pour le revêtement en vinyle (1.83m) réduira la possibililé pour le gaz d’entrer par le capuchon de l’évent. Agence d’Installation Qualifiée L’installation et le remplacement des tuyaux à gaz, des équipements Emplacement de l'Ouverture dans le Mur ou accessoires, la réparation et l'entretien de l'équipement doivent Le radiateur doit être situé...
  • Page 25 7. Attacher la hotte extérieure au côté du radiateur MINIMUM 4" (10.16cm) MINIMUM 4" (10.16cm) AUx MATéRIAUx AUx MATéRIAUx avec (4) vis #8 x 1/4" (6.4mm). Les vis sont fournies. COMbUSTIbLES COMbUSTIbLES 8. Positionner et attacher la hotte intérieure au recouvrement intérieur avec (4) vis #8 x 1/4"...
  • Page 26 Emplacement de l'Alimentation électrique 2. Attacher le tuyau d’échappement de 4" (10.16cm) de diamètre Sur le bas des panneaux des côtés gauche et droit, il y a une entrée sur le collet de la sortie d’échappement qui est sur la chambre défonçable de 7/8"...
  • Page 27 CALFEUTRER 4. Appliquer du ciment pour radiateur au collet de la sortie CALFEUTRER d’échappement de 4" (10.16cm) de diamètre et sur le collet PLAQUE Ex- PLAQUE Ex- TéRIEURE DE de 4" (10.16cm) de diamètre du capuchon d’évent. Attacher TéRIEURE DE MONTAGE MONTAGE le tuyau de sortie d’échappement de 4"...
  • Page 28 bONDE NPT DE 1/8" (3.175mm) POUR véRIFIER LE jAUGEAGE DES TUyAU D’ALIMENTATION vALvE vUE DE DESSUS CONNExIONS. EN GAZ RéGULATEUR DE PRESSION évENT vALvE à PRISE POUR SORTIE DE CLé UNIvERSELLE vALvE DE FERMETURE PRESSION MANUELLE RACCORD HORIZONTAL ENTRéE DE GAZ SORTIE DE GAZ ARRIvéE PRISE POUR PRESSION...
  • Page 29 AjUSTEMENT CONvENAbLE DE LA FLAMME Pose des Fils électriques Si vous utilisez une source électrique extérieure, l’appareil, lorsqu’il est installé, doit avoir une prise de terre conforme avec les codes locaux ou dans l’absence de codes locaux, avec le National Electrical Code, ANSI/NFPA70 ou Canadian Electrical Code, CSA C22.1.
  • Page 30 POUR vOTRE SéCURITé LIRE AvANT D’ALLUMER AvERTISSEMENT: Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil a une veilleuse qui doit être allumée manuel- instructions du fournisseur de gaz.
  • Page 31 SUGGESTIONS POUR LE SERvICE ET L’ENTRETIEN. APPELER UN TEChNICIEN D’ENTRETIEN GéNéRAL : Tous les radiateurs ont reçu un test d’allumage 2. Vérifier l’ajustement de la veilleuse, il doit être complète- pour vérifier le bon fonctionnement. Ceci inclus la flamme du ment ouvert ( dans le sens opposé...
  • Page 32 S’IL vOUS PLAîT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro Numéro Numéro d’index de la pièce d’index de la pièce Description Description 11763 Dessus de la paroi extérieure Dv-781 Assemblage du couvercle de 632024...
  • Page 33 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62220-2623 12431-9-1109 Page 13...
  • Page 34 NoTES DE SERVICE Page 14 12431-9-1109...
  • Page 35 NoTES DE SERVICE 12431-9-1109 Page 15...
  • Page 36 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. Comfort Systems www.empirecomfort.com Page 16 12431-9-1109...