Maintenance • Mantenimiento
Entretien • Manutenção
Prefilter
Adsorption filter
Prefiltro
Filtro de adsorción
Préfiltre
Filtre d'adsorption
Filtro de
Filtro de adsorção
entrada
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
gals./l
gals./l
1 x 0.5
1 x 0.8
1 x 2
1 x 3
(conical)
1 x 1.2
1 x 2.1
1 x 4,5
1 x 8
(conical)
1 x 2.4
1 x 4.5
1 x 9
1 x 17
(conical)
24 h
H2O
20
Weight
Dimensions
Peso
Dimensiones
Poids
Dimensions
Peso
Medidas
lbs./kg
inch/mm
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
2.2
1,0
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
6.6
3,0
ø 9.5" (240)
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
1 2 3 4 5 6 7 8 9 0
9.9
1 2 3 4 5 6 7 8 9 0
4,5
Filter replacement
Order Ref.
Referencia
This is necessary when
No. de comm.
- the water being discharged is too
No de encomenda
cloudy (see 'Wastewater test')
- the filter is clogged (see 'Checking
of level indicator')
Note:
• Please observe the legal regulati-
ANAQUA2FLTR
ons in your country pertaining to
the use and handling of filters, par-
ticularly with regard to keeping a
spare filter set.
• Only use OEKOSORB filter sets in
ANAQUA4FLTR
order to ensure operational reliabi-
lity. OEKOSORB filters can be
identified by their labelling and the
test seal.
• Do not use any other filters, since
the official approval of the de-
vice would no longer be appli-
ANAQUA5RFLTR
cable in such a case. Furthermo-
re, the correct functioning of the
AQUAMAT (wastewater quality,
throughput capacity, filter service
life) could not be guaranteed.
• Soak new filter in water for 24 hours.
Procedure
1. Place new OEKOSORB filter set
near the unit. Keep the PE pak-
kaging of the new set for putting in
the old filters.
2. Shut off condensate inlet (see
"Cleaning of dirt collector" page
22)!
3. Open AQUAMAT lid.
4. Remove overflow pipe by turning
(use gloves supplied).
5. Lift filter and allow it to drain.
Place filter into the PE bag and
close bag tightly.
6. Clean filter area and overflow.
7. Insert the new filter slowly, pu-
shing it downwards by hand only.
8. Put back the overflow pipe and the
lid.
9. Open condensate inlet.
10. Ensure correct disposal of the
fouled filter.
english