Télécharger Imprimer la page

KAESER AQUAMAT 2 Instructions De Montage Et De Service page 18

Publicité

Maintenance • Mantenimiento
Entretien • Manutenção
18
¾
english
Weekly wastewater test
• Fill test jar at the sampling cock.
• Compare the cloudiness with the
reference jar.
If the sample is clearer than the
reference cloudiness
! the filter is O.K.
If the sample is cloudier than the
reference cloudiness
! the filter needs to be changed!
NOTE: Never pour any foreign li-
quid into the pressure relief
chamber! This can impair the filter
efficiency of the AQUAMAT.
Checking of oil collector
• When the oil collector is ¾ full, it
should be replaced with another one.
• The collected oil must be disposed
of as waste oil:
No oil discharge:
Depending upon the actual throughput
and the type of condensate, it may in
some cases be months before the oil
starts flowing into the collector. The
oil discharge will only start when a
sufficiently thick layer of oil has built
up inside the AQUAMAT.
Water in the oil collector:
• Oil outflow is set too low (see 'Putting
into operation', page 16).
• AQUAMAT is sometimes overloaded
! check compressor performance
(see page 6).
! Check condensate discharge
points
only use ECO-DRAIN device
observe ECO-DRAIN manual
Checking of level indicator
Level indicator has risen
• Clogged filter
! Check filter condition, change
filter if necessary.
• Obstruction in water outlet
! Clear the outlet.
• AQUAMAT overloaded
! Check compressor perfor-
mance.
Checking for leaks
• Inspect hoses and connections,
tighten screws where necessary or
replace parts.
• Is the container in a good condition?
Contact the manufacturer in the
event of leakage.
AQUAMAT 2, 4, 5R

Publicité

loading

Ce manuel est également adapté pour:

Aquamat 4Aquamat 5r