English
20
Problem
The coffee is watery.
The coffee is not hot
enough.
Coffee does not come
out or coffee comes out
slowly.
Cause
The brew group is dirty or
needs to be lubricated.
The machine is performing its
self-adjustment procedure. This
procedure is started
automatically when you use
the machine for the first time,
when you change to another
type of coffee beans or after a
long period of non-use.
The grinder is set to a too
coarse setting.
The temperature is set too low. Set the temperature to the maximum
The automatic rinsing cycle is
disabled.
A cold cup reduces the
temperature of the drink.
Adding milk reduces the
temperature of the drink.
The AquaClean water filter was
not prepared properly for
installation.
Solution
Remove the brew group (see
'Removing the brew group from the
machine'), rinse it under the tap and
leave it to dry. Then lubricate the
moving parts (see 'Lubricating the
brew group').
Brew 5 cups of coffee initially to allow
the machine to complete its self-
adjustment procedure.
Set the grinder to a finer (lower)
setting. Brew 2 to 3 drinks to be able to
before taste the full difference.
setting. To adjust the temperature,
press the 'Settings'
Activate the automatic rinsing cycle by
pressing press the 'Settings'
When this setting is activated, the
machine will heat up and perform an
automatic rinsing cycle when you turn
on the machine.
Preheat the cups by rinsing them with
hot water.
Regardless of whether you add hot or
cold milk, adding milk always reduces
the temperature of the coffee. Preheat
the cups by rinsing them with hot
water.
Remove the AquaClean filter and
dispense some hot water. If this works,
the AquaClean filter was not installed
properly. Reinstall and activate the
AquaClean filter and follow all steps in
chapter 'AquaClean water filter'.
After a long period of non-use, you
need to prepare the AquaClean water
filter for use again and dispense 2-3
cups of hot water.
icon.