PARAMETER CHECKING AND ADUSTMENT
Parameter list
Some parameters can be checked and adjusted by the controller. Below is the parameter list.
Parameter
No.
0
Tank water setting temp.
Water temperature
1
2
E-heater setting temp.
3
4
Week disinfection temperature
5
High temp disinfection time
6
7
Defrosting entry coil temp.
8
Defrosting exit coil temp.
9
Max defrosting cycle period
Electronic expansion valve
10
11
Target over-heat degree
Steps of manually adjusting
12
the electronic expansion valve
Disinfection start up time
13
Parameter of solar water
14
High temp disinfection
15
16
Temperature setting mode
17
18
Set temp without PV
20
Return water pump stop time
21
Return water pump running time
Whether
22
auxiliary heating need to be
turned on
23
24
DC fan speed setting
Host communication
25
address setting
A
Lower part tank water temp. -9 ~ 99°C
B
Upper part tank water temp.
Description
gap to restart
E-heater delay time
Defrosting period
adjustment
adjusting
pump
interval
Set temp with PV
the
defrost
Fan type
Range
Default
10 ~75°C
50°C
2 ~ 15°C
5°C
10 ~85°C
55°C
0~90min
6
50 ~75°C
70°C
0 ~ 90min
30 min
30~90min
45 min
-30~0°C
-7°C
2 ~ 30°C
6°C
1 ~ 12min
8 min
0/1
1
-9 ~ 9°C
5°C
10 ~ 50step
35 step
23
0~23
0
0/2
7
1-28day
0/1
0
10-75℃
60
10-75℃
50
1-99*10min
3
1-30min
3
0/1
0
0/1
0
50-140
88
1-16
1
Actual testing value. Error code P1 will
be shown in case of a malfunction
-9 ~
Actual testing value. Error code P2 will
99°C
be shown in case of a malfunction
38
Remarks
Adjustable
Adjustable
Adjustable
t * 5 min
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable (0-manual,1-auto)
Adjustable
Adjustable
Adjustable(hour)
Adjustable( 0 without
water pump,1 with
water pump, 2
Return water pump)
Adjustable
Adjustable (0-manual,1-auto)
Adjustable
Adjustable
Adjustable by N*10 min
Adjustable
0 - Off, 1 - On
0 - AC, 1 - DC
Adjustable N*10RPM
Using communication port CN5