OPERATION
LED Operating Code Display
ALARM SILENCED
PUMP ACTIVITY
AC POWER
=
LED is ON Continuously
When the System Alert light IS NOT flashing, refer to Figure 6.
When the System Alert light IS flashing, refer to Figure 7 .
All of the situations listed above indicate normal system operation; no action is required. However, if the BBU pump is running or
has run, check the primary pump and actively monitor the charger status for battery life. Always reset the charger after the pump
runs.
During normal system operation, the SYSTEM ALERT LED blinks while the float switch is on,indicating the pump should start
within 3 seconds. The "AC POWER" LED is lighted (solid or blinking) as long as the system is plugged in to an operating AC power
circuit.
CONTROL LED
AC Power
Pump Status
Silenced Audible Alarm
Charging
Battery Status
System Alert
FP979 (06-08-20)
SYSTEM ALERT
CHARGING
BATTERY STATUS
Indicates
Indicates
Indicates
Indicates
Indicates
Indicates
Indicates
Indicates
Indicates
=
LED is Flashing (Fast)
Figure 6: Operating Code Displays
(LEDs Lighted Continuously or Flashing)
CONTINUOUS ILLUMINATION INDICATES NORMAL OPERATION
AC power is present. Unit is online.
The float switch has been activated. The LED remains on (flashing) after the pump has stopped.
Depress the 'System Test' button to reset it.
Audible Alarm has been silenced. Press and release the 'Silence Alarm' button to reset (activate) the
audible alarm and turn OFF the LED.
Indicates that the battery is charging – see Table II, above.
Continuous ON - the battery voltage is above 10.9 Volts DC and capacity is above 20%.
Slow Beep/Slow LED Flash - the battery's capacity is below 20%, and voltage is between 8.2VDC and
10.9VDC.
Fast Beep/Fast LED Flash - the battery has been discharged to less than 8.2VDC.
Flashing (in unison with the buzzer) indicates that the charger has entered 'Failure Mode'. Press the
System Test and Silence Alarm buttons to reset it. If the source of the failure is not corrected, the
charger will reenter Failure Mode. See Table IV for error code information.
Table II: LED Function Displays (LEDs Lighteded Continuously)
System Operating Condition
115V AC Power is connected / Unit online
115V AC Power is connected / Unit o ine
Pump is running (continuous LED)
Fast ashing LED: Pump has run
Audible alarm is switched off
Fast ashing LED: Battery pre-quali cation test is running
Battery is charging normally
Continuous LED: battery charge is above 20%,
system is maintaining charge
Slow ashing LED: battery charge is below 20%
=
LED is Flashing (Slow)
=
LED is OFF
6790 0313
13