No electrical leakage
Unit is properly grounded
All electrical terminals properly covered
Indoor and outdoor units are solidly installed
All pipe connection points do not leak
Water drains properly from drain hose
All piping is properly insulated
Unit performs COOL function properly
Unit performs HEAT function properly
Indoor unit louvers rotate properly
Indoor unit responds to remote controller
DOUBLE-CHECK PIPE CONNECTIONS
During operation, the pressure of the refrigerant circuit will increase. This may reveal leaks that were not pres-
ent during your initial leak check. Take time during the Test Run to double-check that all refrigerant pipe con-
nection points do not have leaks. Refer to Gas Leak Check section for instructions.
5.
After the Test Run is successfully completed, and you confirm that all checks points in List of Checks to
Perform have PASSED, do the following:
a. Using remote control, return unit to normal operating temperature.
b. Using insulation tape, wrap the indoor refrigerant pipe connections that you left uncovered
during the indoor unit installation process.
IF AMBIENT TEMPERATURE IS BELOW 16°C (60°F)
You can't use the remote controller to turn on the COOL function when the ambient temperature is below
16° C. In this instance, you can use the MANUAL CONTROL button to test the COOL function.
1.
Lift the front panel of the indoor unit, and raise it until it clicks in place.
2.
The MANUAL CONTROL button is located on the right-hand side of the unit. Press it 2 times to select the
COOL function.
3.
Perform Test Run as normal.
Manual control button
4
186
man_S60xx EU ('24) TD.indd 186
man_S60xx EU ('24) TD.indd 186
List of Checks to Perform
PASS / FAIL
Outdoor (2):
Indoor (2):
22-01-2024 11:56
22-01-2024 11:56