Télécharger Imprimer la page

Napoleon GX70NT Instructions D'installation Et D'opération page 7

Modèle au gaz naturel / au propane

Publicité

Les langues disponibles

Les langues disponibles

2.3
GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
Altitude (FT)
Max. Input (BTU/HR)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply
Pressure
Manifold Pressure (Under Flow
Conditions)
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
No external electricity (110 volts or 24 volts) is required for the gas millivolt system operation.(MILLIVOLT
ONLY)
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
When the appliance is installed at elevations above 4,500 ft (1372m), and in the absence of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating
shall be reduced at the rate of 4% for each additional 1,000 ft (305 m).
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
RATES AND EFFICIENCIES
NG
0-4,500
35,000
4.5" (11mb) w.c.
7" (17mb) w.c.
3.5" (9mb) w.c.
QUALITY!
GX70
LP
0-4500
32,000
11" (27mb) w.c.
13" (32mb) w.c.
10" (25mb) w.c.
7
EN
W415-1519 / C / 11.06.15

Publicité

loading

Ce manuel est également adapté pour:

Gx70nteGx70ptGx70pte