EN
SYMPTOM
White / grey fi lm
forms.
Flames are very
aggressive.
Main burner fl ame
is a blue, lazy,
transparent
fl ame.
Main burner goes
out: pilot goes out.
W415-1519 / C / 11.06.15
PROBLEM
Sulphur from fuel is being
deposited on glass, logs or
combustion chamber
surfaces.
Door is ajar.
Venting action is too great.
Outer air intake pipe is not
sealed or is damaged
Blockage in vent.
Compromised venting.
Vent recirculation.
TEST SOLUTION
-
Clean the glass, see "CARE OF GLASS" section
-
DO NOT CLEAN GLASS WHEN HOT.
-
If deposits are not cleaned off regularly, the glass
may become permanently marked.
-
Tighten door clamps if applicable.
-
Restrict vent exit with restrictor plate. See
"RESTRICTING VENTS" section if applicable.
-
Reseal venting or replace damaged section
-
Remove blockage. In extreme conditions, ice
buildup may occur on the terminal and should be
removed. To minimize this from happening again,
it is recommended that the vent lengths that pass
through unheated spaces (attics, garages, crawl
spaces) be wrapped with an insulated mylar sleeve.
Prevent sleeve from sagging. Contact your local
authorized dealer for more information.
-
Check venting system parameters (seal, length,
rise, etc.).
-
Check joint seals and installation.