Issue
LED flashing.
LED is lit up despite
the drip tray being
empty.
LED flashing and all
beverage LEDs
flashing.
LEDs
,
and
flashing.
LEDs
and
flashing.
LEDs flashing.
and
up.
Cause and troubleshooting
Wait 1 hour so the appliance can cool down.
2.
Appliance is switched off and does not detect emptying.
Switch the appliance on and remove the drip tray.
1.
Reinsert the drip tray.
2.
Water tank is missing or wrongly inserted.
Insert the water tank correctly.
Pipe system in the appliance is dry.
Insert the water tank correctly.
Fill the water tank with fresh, cold, non-carbonated
water.
Air in the water filter.
Immerse the water filter in water with the opening
1.
facing upwards until no more air bubbles escape.
Reinsert the filter.
2.
Ambient temperature is too cold.
Operate the appliance at temperatures over 41 °F
(5 °C).
Brewing unit is heavily soiled or cannot be removed.
Restart the appliance.
Clean the brewing unit.
Appliance has an error.
Restart the appliance.
lit
Descaling process was interrupted.
Proceed as described in section
→  "Resetting a service program", Page 28 .