Installation
Rough-In Dimensions for Supplies and Drain
Notes
Maximum flow rate required to washfountain is 1.5 GPM. Size supply lines accordingly.
Supplies from Below: Stub up 2-1/2" (64).
Supplies from Above: Supplies must be located on centers of dimensions shown to pass
through washfountain shroud and sprayhead.
Drain through floor: Stub up 3" (76).
Supplies from Below or Through Wall
Type A
Off-line vent (P-Trap
supplied by Installer.)
Top View
2-9/16"
(65)
6-3/4"
(298)
7-15/16"
(202)
11-3/4"
(298)
When running supplies and drain through wall, use same horizontal measurements as shown in Top View.
Position openings above the fi nished fl oor, at the following dimensions (to center):
Drain:
Floor-mounted units: UPC and IPC restrict the vertical
distance from the fi xture outlet to the trap weir to not more
than 24" (610). Check state and local codes for variances.
Bradley Corporation • 215-923 Rev. H; EN 10-00-015
Type H
Centrally rising vent -
passes through center of unit
(P-Trap furnished).
11-3/4"
(298)
Optional Wall
DRAIN
12-1/16"
(306)
C
H
12-1/16"
(306)
18-7/16"
(468)
Standard Height: 19-1/4" (305)
Juvenile Height: 15-1/4" (387)
Type B
Centrally rising vent -
passes through center of unit
(P-Trap furnished).
6-3/4"
(298)
11-3/4"
18-7/16"
(298)
(468)
Supplies: Standard Height: 12" (305)
Juvenile Height: 8" (203)
SN2013/IR, SN2033/IR
Key
1/2" Supply: Nominal Copper Tube
1/2" Supply Through Wall (Optional): Nominal Copper Tube
1-1/2" NPT Drain
Supplies from Above
Top View
11-3/4"
(298)
Optional Wall
DRAIN
10-5/16"
(262)
C
H
10-5/16"
(262)
11-1/2"
(292)
7-12-2010
(mm)
Type O
Off-line vent (P-Trap
supplied by Installer.)
11-1/2"
(292)
5