Installation
Supplies required for installation:
• 3/8" diameter bolts and floor/wall anchors to anchor washfountain pedestal to floor and wall
• 1/2" hot and cold water supply lines and fittings
• 1/2" nom. copper tubing supply lines for types with supplies from above
• Standard P-trap (trap included with "B" or "H" drain type and some optional equipment)
• 1-1/2" drain lines and fittings
• Pipe sealant
• 110 VAC power source and conduit box for 110/24 VAC hard-wired transformer (supplied)
• 18-gauge two-conductor lamp cord with female connectors
Supplies recommended for installation:
• 1-1/2" vent or tie pipe on types vented through washfountain column
• Caulk (may be applied between backsplash and bowl to avoid debris accumulation)
• Electrical cut-off switch to the unit. This feature prevents accidental water delivery during regular maintenance and service.
Dimensions - Sentry
Corner with Infrared Control
43-3/4"
(1111)
25-1/16"
18-3/4"
(637)
(476)
Standard height floor-mounted models with
Infrared or hand control are ADA compliant.
Juvenile Height dimensions, where
different, are shown in Italics.
Bradley Corporation • 215-923 Rev. H; EN 10-00-015
™
Corner Washfountain
45-5/8" (1159)
41-5/8" (1057)
42-9/16" (1081)
48-9/16" (797)
33-7/16" (849)
29-7/16" (747)
29-9/16" (751)
25-9/16" (649)
9" (229)
5" (127)
13-5/16"
(338)
Wall-Mounted with Infrared Control
43-3/4"
(1111)
13-5/16"
(338)
25-1/16"
18-3/4"
(637)
(476)
7-12-2010
SN2013/IR, SN2033/IR
(mm)
45-5/8" (1159)
41-5/8" (1057)
42-9/16" (1081)
48-9/16" (797)
33-7/16" (849)
29-7/16" (747)
29-9/16" (751)
25-9/16" (649)
9" (229)
5" (127)
3