System messages
LED
Malfunction
Flashes
No automatic clean-
green/red
ing cycle within
48 hours
No flow of water
No water detected
by the sensor
Flashes red 20 automatic clean-
ing cycles in succes-
sion
Flashes
ScreenMatic screen
green
not rotating alt-
hough manual
cleaning was trig-
gered.
30
Possible cause
Sensor soiled
No dirty water, cleaning
is not necessary
Filter pump is not oper-
ating
Control device incor-
rectly positioned
Control device defec-
tive
Insufficient conductiv-
ity of the water
Insufficient pump ca-
pacity
ScreenMatic screen
soiled
Sensor soiled
Control device incor-
rectly positioned
Pump capacity too high Adjust the pump capacity
Motor cable plug not
connected or incor-
rectly connected to the
control device
Motor defective
Remedy
• Clean the sensor.
• Descale the sensor.
–
Start up the filter pump.
Correctly position the
control device
Replace the control de-
vice.
Increase the water hard-
ness with OptiPond
Adjust the pump capacity
accordingly
• Start manual cleaning
and use a brush to
clean the ScreenMatic
screen on the side of
the water distributor
(→ Manual cleaning)
• Clean the ScreenMatic
screen from the inside
if the mesh is clogged
by a biofilm
(→ ScreenMatic screen)
Clean the sensor.
Correctly position the
control device
accordingly
Connect the plug, check
that it is correctly seated.
Replace motor
Resetting the sys-
tem message
Automatic reset af-
ter remedy of mal-
function
Automatic reset af-
ter remedy of mal-
function
–