No. (x) compressor high DC bus current protection
xP33
xP32 protection occurs 3 times in 100 minutes
High AC voltage protection
P51
P52
Low AC voltage protection
Power supply BN connect protection, or the phase is missing, or
P53
unbalanced when powered on
DC bus low voltage protection
P54
DC bus ripple wave protection, or the phase is missing, or unbalanced
P55
when powered on
xP56
No. (x) Inverter module DC bus low voltage error
No. (x) Inverter module DC bus high voltage error
xP57
No. (x) Inverter module DC bus excessively high voltage error
xP58
EEPROM error
P71
-
Pb1
Anti-condensation protection
Pd1
Pd2
Pd1 protection occurs 2 times in 60 minutes
1b01
Electronic expansion valve (EEVA) error
2b01
Electronic expansion valve (EEVB) error
3b01
Electronic expansion valve (EEVC) error
4b01
Electronic expansion valve (EEVD) error
bA1
-
Note: 'x' is a placeholder for the fan or compressor address, with 1 representing fan A or compressor A and 2 representing fan
B or compressor B.
Table 7.4 Installation and debugging error code
Error code
U11
Outdoor unit type setting error
U12
Capacity setting error
U21
The system contains the 1
U31
No test run or unsuccessful test run, please re-enter the test run.
U32
Outdoor temperature out of operating range
U33
Indoor temperature out of operating range
U34
Outdoor and indoor temperature out of operating range
U35
Liquid side stop valve is not opened
U37
Gas side stop valve is not opened
U38
No address
U3A
The communication cable is connected incorrectly
U3b
The installation environment is abnormal
U3C
Auto mode error
U41
Common indoor unit exceeds the allowable connection range
U42
Fresh Air Processing indoor unit exceeds the allowable connection range
U43
AHU kit (discharge air temperature control) is out of the allowable connection range
U44
AHU kit (return air temperature control) is out of the allowable connection range
U48
The total capacity of the indoor unit is out of the allowable connection range
U51
Detected more than one outdoor unit in the individual VRF system
U53
Detected different series outdoor units in the same VRF system
Error description
generation indoor unit or the indoor units address are repeated
st
07
NO
YES
NO
NO
YES
NO
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
Manual re-start
required
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
NO
YES
YES
YES
YES
YES
YES
YES
V.1

Publicité

loading

Ce manuel est également adapté pour:

Jr8 8-14hpJr8 16-18 hpJr8 20-22hp