Shove the choke to about halfway to restart a warm
motor.
A hot motor will not start if there is too
much fuel in the cylinder.
If this happens, wait five to ten minutes
before trying again. Shove the choke
completely to the right and the motor
should start.
Set the motor switch in the "ON"-position.
Pull slightly on the start cord 5 until you feel resistance
and then yank hard and swiftly.
Do not let the start cord retract by itself:
guide it back by hand. Hold the carrying
handle firmly to prevent the generator from
falling over when you pull the start cord.
Press the choke in completely after the engine is
started.
If the engine stops and will not restart,
check
the
engine
troubleshooting in other areas.
3.3 SYSTEM LOW OIL WARNING
The equipment does not start if the oil level is low.
3.4 AUX OUTPUT 12V
The 12 Vdc auxiliary connection can be used while
using the AC output. The typical use of this output is to
charge a lead acid battery. see 2.5.
A DC overload, disconnect the DC circuit protector. If
this happens, unplug the DC load before resetting the
circuit protector to resume operation.
3.5 OVERLOAD
The team cut the electricity supply if a consumer
exceeds the maximum, to restore supply shut off the
engine and start it again in the models GID (Inverter).
In AVR moldelos reset the circuit breaker 13.
3.6 STOPPING THE ENGINE
To stop the engine in an emergency, turn the engine
switch to the OFF position.
In normal use:
Switch off the connected equipment and pull the
inserted plug out.
Turn the engine switch to the OFF position.
Turn the cap lever fully counter clockwise to the "OFF"
position.
Be sure both the fuel cap lever and the
engine switch are in "OFF" position when
stopping, transporting and/or storing the
generator.
3.7 ELECTRICAL INSTALLATION
The electrical system will be mandatory for attesting
authorized in writing their work.
Connections for standby power to a building's electrical
system must be made by a qualified electrician and
must comply with all applicable laws and electrical
codes. Improper connections can allow electrical
current from the generator to back feed into the utility
lines. Such back feed may electrocute utility company
workers or others who contact the lines during a
power outage, and when utility power is restored, the
generator may explode, burn, or cause fires in the
building's electrical system.
To prevent electrical shock from faulty appliances, the
generator should be grounded. Connect an electric
conductor (cable) of at least 1.5mm² between the
generator's ground terminal and an external ground
source.
Limit operation requiring maximum power to 30
oil
level
before
minutes. For continuous operation, do not exceed the
rated power. In either case, the total wattage of all
appliances connected must be considered.
Do not exceed the current limit specified for any one
receptacle.
Do not modify or use the generator for other purpose
than it is intended for. Also observe the following when
using the generator:
- Do not connect generators in parallel.
- Do not connect an extension to exhaust pipe.
- When an extension cable is required, be sure to use
a rubber sheathed flexible cable.
- Limit length of extension cables: 60m for cables of
1.5mm
- Keep the generator away from other electric cables
or wires such as distribution network.
3.8 LOCATION AND TROUBLESHOOTING
Engine will not start:
Shake the generator several times to make the float
rise if the generator cannot start after adding oil for
the first time and the oil alarm indicator stays on when
pulling the starting grip.
Make sure there is no spilled fuel around the spark
plug. Spilled fuel may ignite.
If the engine still doesn't start, have the generator
repaired by a licensed repair person.
-
21
and 100m for cables of 2.5mm
2
NO
Enough fuel?
Yes
Are the engine switch and fuel
NO
valve "on"?
Yes
Enough lubricating oil?
NO
Yes
Is there fuel in the carburetor?
NO
Yes
NO
Spark plug works or
Replace spark plug.
not?
Is the output indicator on?
NO
Is the overload
NO
indicator on?
Yes
Does the electrical equipment
NO
work when plugged in directly?
Yes
-
NO
Is the electric
circuit breaker intact?
Yes
.
2
Add fuel.
Turn them to the "on" position.
Add more qualified oil.
Start a few times to ensure that
fuel enters the carburetor.
NO
Send the generator
to an authorized dealer
Send the generator to an
authorized dealer.
Restart after turning off the
overload indicator.
Yes
Send the generator to an
authorized dealer.
Replace the electric equipment.
Repair the electric equipment.
Replace the electric circuit breaker.
Send the generator to
es
it
gb
fr
p