VAS 6380B / VAS 6381B
7.6
Editing default values
The AirConServiceCenter has preset values for the most important
service tasks. The default values appear automatically when you select
the respective menu.
You can alter the following default values if necessary:
Parameter
Pressure increase Test time
Vacuum time min.
Leak Test
PAG Oil
UV Tracer
Filling Qt. g.
Print recovery value ?
1. In the basic menu, use the cursor keys  or  to select
"Other selections":
2. Press ENTER to confirm.
3. Use the cursor key  to select "Service.".
4. Press ENTER to confirm.
5. Enter the password "7388".
6. Use the keypad and the cursor keys to enter the information.
7. Press ENTER to confirm.
8. Press STOP to access the standby menu.
EN
min.
min.
ml. (additional quantity)
ml.
S h o rt s e l e c t i o n
F r e e s e l e c t i o n
O t h er s e l e c t i o n s
E N T ER - O K S T O P - E X I T
Initial start-up
Default value
1
20
4
0
7
500
Yes
87