SAFE TOP OPEN PLUS SMART
MASTER KEY
The Master Keys are the "secondary" keys; they are necessary for Safe opening in case of emergency.
SET MASTER KEY (MODE 1 – MODE 2)
1.
Press "*" button with one acoustic signal ("beep").
2.
Put owner key on the receiver, after one acoustic signal ("beep") put owner key on the receiver again.
After one acoustic signal ("beep"), the display will show twinkling "P"
3.
Put another IB key (blue) on the receiver, after one acoustic signal ("beep") the display will show "P_S1",
the IB key becomes the Master Key. Before the twinkling P disappear, the master keys can be set
continue and the display will show "P_S2...P_S5", each safe only can be set with 5 master keys
SAFE OPENING WITH THE MASTER KEY
Place on the receiver the Master Key; an acoustic signal ("beep") sound and the display show "OPEN" and
the Safe is opening
DELETE ONE MASTER KEY WITH KEY IN HAND (MODE 1 – MODE 2)
1.
Press "*" button with one acoustic signal ("beep").
2.
Put owner key on the receiver, after one acoustic signal ("beep") put owner key on the receiver again,
after one acoustic signal("beep") the display will show twinkling "P"
3.
Put the Master Key that shall be deleted on the receiver, after two acoustic signal ("beeps") the display
will show "P_S..", the Master Key is deleted.
DELETE ONE MASTER KEY WITHOUT KEY IN HAND (MODE 1 – MODE 2)
1.
Press "*" button with one acoustic signal ("beep").
2.
Put owner key on the receiver, after one acoustic signal ("beep") put owner key on the receiver again,
after one acoustic signal ("beep") the display will show twinkling "P"
3.
Input the Master Key ID that shall be deleted, after two acoustic signal ("beeps") the corresponding
Master Key is deleted.
DELETE ALL MASTER KEYS (MODE 1 – MODE 2)
1.
Press "*" button with one acoustic signal ("beep")
2.
Put owner key on the receiver, one acoustic signal ("beep"),
3.
Put owner key on the receiver twice, the display will show "P_ED", that means all the master keys was
deleted.
WARNING! At this point the Master Key cannot open the Safe anymore; to reactivate it follow again the
above described procedures
SAFE TOP OPEN PLUS SMART_IM_20220121
26