Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction 1.9727 mg/L 2.0 mg/L ± 10%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
■
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■
Use replacement filter P6RFWG2K, P6RFGEG2K,
P6RFKG2K, Part Number ICE2.
Style 1 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you
replace the filter.
Style 2 – Press FILTER to check the status of your water filter.
If the filter indicator light is yellow and the words "ORDER
FILTER" appear on the display screen, order a new filter. If the
filter indicator light is red, it is recommended that you replace
the filter.
■
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
■
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
®NSF is a registered trademark of NSF International.
20
20
20
20
20
20
PERFORMANCE DATA SHEET
Ice Maker Water Filtration System
System tested and certified by NSF
International against NSF/ANSI
Standard 42 for the reduction of
Chlorine Taste and Odor.
Average
Influent Challenge
Influent
Concentration
Maximum
Average
Effluent
Effluent
0.71 mg/L
0.7788 mg/L
■
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
■
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Average %
Reduction
Reduction
70.2
72.81
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.50 gpm (1.89 Lpm) @ 60 psi