Télécharger Imprimer la page

Samsung WA40A3A Serie Mode D'emploi page 217

Publicité

Les langues disponibles

Les langues disponibles

STEP 3 Connect the electrical wiring
First, read through the "Electrical requirements" section, and follow these steps.
3-wire system
A
B
C
L2
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E.
/
" (1.9 cm) UL-listed strain relief
3
4
DV3000A(SEM)_DC68-03784P-00_EN.indd 25
1. Loosen or remove the screws from the
2. Connect the neutral wire (white or
3. Connect the other wires to outer
D
4. Tighten the strain relief screws.
L1
5. Insert the terminal block cover into the
E
• To convert from the 4-wire system to
• Ring-type terminals are recommended.
• Connect the power cord and check L1/
center terminal block.
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
terminal block screws. Tighten the
screws.
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
the 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
If using strap terminals, make sure they
are tightened.
L2/N voltage. If the voltage is low, it
may not heat properly. Review the
"Electrical requirements" section on
page 19 if needed.
English 25
2020-12-07
4:50:54

Publicité

loading

Ce manuel est également adapté pour:

Wa41a3a serieWa40a3005aw-g-kitWa40a3005awDvg41a3000w