OPTIONAL LINERS
For installations where the PMA400SS unit is less than 30"
above cooktop, this powerpack insert should be mounted
into a metal liner (FIG . 4) to protect cabinetry combustible
material from heat, in order to meet building code
requirements . This will allow easier cleaning and provide
protection to the cabinetry . Refer to table at right to find the
liner model corresponding to the cabinet style and width .
Visit www .broan-nutone .com or www .broan-nutone .ca to view
specific model information .
REMOVE THE ADAPTER/DAMPER
Detach and set aside the 3¼" x 10" adapter/damper (grey part
in FIG . 5) from the side of the powerpack insert by removing
its 2 retaining screws . Discard the screws .
REMOVE THE CABINET BRACKETS
Detach the cabinet brackets (grey part in FIG . 6) from the back
of the powerpack insert by removing its 4 retaining screws .
Discard the screws .
Fold up and down the bracket until it is split in two separate
parts (FIG . 7) . Keep the brackets for possible further use .
NOTE: Both cabinet brackets have one wide edge and one
narrow edge (FIG . 8), to cover all installation
configurations depending on cabinet widths .
METAL LINER
HD1051