DRAINAGE
EN
Self- evaporating system
The self-evaporating system uses the collected water to cool the condenser coils for
better efficient performance. It is no need to empty the drainage tank in cooling operation
except in drying operation and high humidity conditions. The condensate water evapo-
rates at the condenser and evacuated through the exhaust hose.
For continuous operation or unattended operating in drying and heating operation, please
connect the attached drain hose to the unit. Condensate water can be automatically flow
into a bucket or drain by gravity.
Switch off the unit before operating.
Remove the plug of the water outlet opening, and keep it in safe area.
Securely and properly connect the drain hose and make sure it is not kinked and clear
of obstruction.
Place the outlet of hose over a drain or bucket and ensure that water could freely
flow out of the unit.
Do not submerge the end of hose into water; otherwise it can cause "Air Lock" in the
hose.
To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the drain hose down-
ward toward the floor. It is appropriate that the degree of inclination should exceed
20 degrees.
Straighten the hose to avoid a trap existing in the hose.
CLEANING AND CARE
CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the effici-
ency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not
operate the unit without an air filter, or the evaporator may be contaminated.
1.
Press POWER button to switch off the unit and unplug the power cord.
2.
Remove the filter mesh from the unit.
3.
Use a vacuum cleaner to suck dust from the filter.
4.
Turn the filter over and rinse the air filter under running water. Let the water run
through the filter in the opposite direction of air flow. Set aside and allow the filter to
air dry completely before reinstalling.
14
Switch off the unit and remove the
two air filters.
CLEANING UP OF REFRIGERANT
General Measures:
1.
Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or
below ground level.
2.
Eliminate every possible source of ignition.
3.
Use appropriate personal protection equipment (PPE).
4.
Evacuate unnecessary personnel, isolate, and ventilate area.
5.
Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
6.
Prevent entry to sewers and public waters.
7.
Stop the source of the release, if safe to do so. Consider the use of water spray to
disperse vapors.
8.
Isolate the area until gas has dispersed. Ventilate and gas test area before entering.
Contact competent authorities after a spill.
Rinse the air filter under running
water.
EN