EN
Start-up and Shutdown
Press POWER to turn the unit on.
The unit runs in in FAN as default.
Press MODE button to select the desired operation mode.
Press POWER again to turn off the power.
Operation mode
The unit has five operation modes: Cool, heat, dry, fan, sleep.
A. Cooling your room
Select the cool mode to lower the temperature in your room.
Press MODE button repeatedly until the LED of COOL operation lights up.
Press Up/Down button to adjust the temperature which is displayed on the screen.
The temperature can be set between 16ºC and 32ºC.
Press SPEED button repeatedly until the desired fan speed indicator lights up.
To control the direction of the air flow horizontally, please press the SWING button
on.
Note: The air conditioner stops if the room temperature is lower than selected temperatu-
re.
B. Ventilating your room
Press MODE button repeatedly until the LED of FAN operation lights up.
In ventilation mode the room air is circulated, but not cooled.
Press SPEED button repeatedly to select the fan speed as desired.
C. Drying your room
Press MODE button on the control panel or remote control, the LED of DRY operati-
on lights up. The fan speed is unable to select. User should connect the hose to the
drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and cannot be selected.
D. Sleep mode (this function can only be used with a remote control)
The sleep mode can be activated when in cool mode and heat mode.
In cool mode :
After 1 hour the preset temperature is increased by 1ºC, after another hour the preset
temperature will again be increased by 1ºC.
12
TIMER SETTING (1hour-24hours):
The timer has two ways of operation:
To turn off
Press Timer key to turn on
(When power on)
the timer function.
To turn on
Press Timer key to turn on
(When power off)
the timer function.
Cancel timer
Press Up/Down repeatedly until the LED shows '00'.
Note: when press POWER will also exit the timer setting.
Automatic Defrost
At low room temperatures, frost may buildup at the evaporator during operation. The
unit will automatically start defrosting and the POWER LED blinking. The defrost control
sequence is as follows:
A.
When the unit operates in the cooling operation, drying operation, the ambient
temperature sensor senses the evaporator coil temperature is below -1°C, after the
compressor will stop operating for 10 minutes or the coil temperature up to 7ºC, the
unit restart to cool operating mode.
B.
When the unit operates in the drying operation, once the coil temperature sensor
senses the temperature of the evaporator is below 40ºC and the differential tem-
perature between coil temperature and room temperature is below 19ºC after the
compressor operation for 20minutes, the unit start defrosting for 5 minutes and the
power indicator blinking.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the