System errors
System errors can occur for various reasons� Contact Berger Customer Service if errors persist�
Use the table below for reference and troubleshooting�
For each LED display, the errors are indicated in the following way:
Constant on
Flashing up to 8 times
All system errors are accompanied by an alarm from the remote control, which goes off to-
gether with the fl ashing after about 8 seconds or until the error is corrected� Various errors are
listed below:
(RED) LED Status
Description
Overcurrent (motor)
Overcurrent (battery)
2 Flashing
3 Flashing
Undervoltage
4 Flashing
Overvoltage
5 Flashing
Overtemperature
6 Flashing
Critical
Undervoltage cut-off
M2 Motor driver failure
8 Flashing sign
M3 Motor driver failure
Constant on
Possible cause and measure
Usually caused by overloading the system,
avoid excessive load or steep slopes,
check that the vehicle brakes are not
applied�
Usually caused by a weak/discharged
battery, check the voltage�
Usually caused by an incompatible battery
or when a charging system is present
during operation�
Usually caused by prolonged operation
with a high load�
- Wait 5 minutes until the electronics have
cooled down�
- Divide long trips into shorter „trips"�
Usually caused by a loose or dry connec-
tion in the wiring or the use of a dead
battery�
- Make sure the system is switched off
and check the wiring and condition of
the terminals�
- Check the condition of the battery by
appropriate means (do not rely on the
caravan's internal battery monitor)�
Triggered if no output voltage is detected:
- Possible short circuit on the motor�
- Possible failure of the control system�
Switch the unit off and on again� If the
problem persists, stop using it and con-
tact service@fritz-berger�de�
GB
45