Télécharger Imprimer la page

ADEO SCREEN ELEGANCE PSCHP0200 Manuel D'instructions page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
QUICK MODEL
1)secure brackets with adequate expansion plugs (min. Ø 8 mm); ceiling or wall mount are possible; check they are level;
WITH CASE
2) fasten screen to brackets as per fig.7;
Fig. 7
WARNING: When installing the screen use plugs and screws suitable for the screen's weight and for the type of wall or ceiling on which the mount
brackets are to be fixed, based on the following criteria
Screen width up to cm
Overall weight
ONLY FOR SCREENS WITH "TENSIO" COUNTERWEIGHT TENSIONED SYSTEM
Technical characteristics:
Voltage: 230V
Frequency: ~Hz50
Power: 120W
Torque: 8Nm
Speed: 17Rpm
FIG. 4
Max nr. of cycles: 2
Cable length: 3mt
Mechanical strength:
EN14202 conformant
Operating T° :
from –20 to +55 ° C
END STOP ADJUSTMENT FOR MOTORISED VARIANT ROLLER SCREENS
WARNING - READ CAREFULLY BEFORE PERFORMING ADJUSTMENTS
Adjustments shown on Fig. 8 must be performed by authorised and specialised personnel only. Incorrect performance of the procedures described
may result in damages to the product which will not be covered by guarantee. End stops adjustment varies depending on the motor's position (right
or left side) or on drop of the curtain (front or rear); the diagram on Fig. 8 is sectioned based on these variants. Adjustment is performed with a 4 mm
hex wrench (included).
END STOPS ADJUSTMENT SCREWS ARE POSITIONED IN THE BOTTOM PART OF THE SCREEN, AND NOT IN THE RIGHT OR LEFT HAND
SIDES. DO NOT ADJUST THE END STOPS WHEN UP OR DOWN BUTTON IS ACTIVATED.
WARNING
"UPPER END STOP MUST ALWAYS BE ADJUSTED AT 2mm FROM THE CASE" see picture on the right.
End stop is adjusted so as to allow the projection sheet to wind around the roller at least 1.5 times to avoid the sheet coming loose. Special attention
must be paid when end stops are adjusted in such a way that projection sheet unwinds beyond the factory setting. This is allowed within a limit of 3
cm without posing a risk to the product. Incorrect adjustment of end stops can cause:
-Projection sheet coming away from the roller
-Projection sheet winding the wrong way, with ensuing damage to flatness of the projection surface and to winding mechanisms
-Breaking of bottom end black frame welding (framed screens)
-Excessive strain on motor with possible ensuing damage and activation of motor's thermal resistance
-Excessive winding of the end stop adjustment system with ensuing breaking of the mechanical part
GUARANTEE
Operators are reminded that in cases where seals have been tampered with and where any damages have resulted from incorrect adjustment, repair
interventions shall not be covered by guarantee.
Technical characteristics:
Voltage: 230V
Frequency: ~Hz50
Power: 120W
Torque: 8Nm
Speed: 17Rpm
Max nr. of cycles: 2
FIG. 5
Cable length: 3mt
Mechanical strength:
EN14202 conformant
Operating T° :
from –20 to +55 ° C
Frequency: 433.92 MHz
Transm. range: 150mt
END STOP ADJUSTMENT FOR SCREENS WITH "INTEGRATED RADIO MOTORISED" ROLLER SYSTEM
WARNING - READ CAREFULLY BEFORE PERFORMING ADJUSTMENTS
Adjustments illustrated below must be performed by authorised and specialised personnel only. Incorrect performance of the procedures described
may result in damages to the product which will not be covered by guarantee.
WARNING
"UPPER END STOP MUST ALWAYS BE ADJUSTED AT 2mm FROM THE CASE" see picture on the right.
End stop is adjusted so as to allow the projection sheet to wind around the roller at least 1.5 times to avoid the sheet coming loose. Special attention
must be paid when end stops are adjusted in such a way that projection sheet unwinds beyond the factory setting. This is allowed within a limit of 3
cm without posing a risk to the product. Incorrect adjustment of end stops can cause:
-Projection sheet coming away from the roller
-Projection sheet winding the wrong way, with ensuing damage to flatness of the projection surface and to winding mechanisms
-Breaking of bottom end black frame welding (framed screens)
-Excessive strain on motor with possible ensuing damage and activation of motor's thermal resistance
-Excessive winding of the end stop adjustment system with ensuing breaking of the mechanical part.
GUARANTEE
Operators are reminded that in cases where seals have been tampered with and where any damages have resulted from incorrect adjustment, repair
interventions shall not be covered by guarantee.
The tensioned screen is supplied with hinged blocks and lateral cables, which are adjusted in the screen's testing phase.
The blocks, however, can be adjusted at a different angle after purchase.
If you wish to change the position of the blocks to achieve a different aesthetic result, proceed as follows:
- Loosen the screw at the back of the block to release the cable.
- Choose the angle you prefer, making sure that the block still tenses the cable.
Tighten the screw at the back of the block to secure the cable.
- Follow the same procedure on the opposite side, ensuring that the two blocks are in the same position.
- Cut off excess cable.
If you do not intend to change the blocks' position, cut off excess cable.
WARNING: Once the cables have been cut it is no longer possible to lower the counterweights any further
MOTORISED VARIANT ROLLER SCREENS
ELECTRICAL CONNECTION: electric cabling must be conformant with applicable IEC standards. IEC norm EN 60335-1
requires that supply network be fitted with an omnipolar selector switch with contact opening distance of at least 3 mm. For
the screen's control use only the selector switch provided by manufacturer, or equivalent model, and follow the instructions of
the connection diagram shown on Fig. 4 (if the motor is mounted on the left, the colours of the wires must be inverted, i.e.
descending = brown, ascending = black). The selector switch must be mounted within sight distance of the product, at a 1.5 -
1.8 m height from the floor.
WARNING: Correctly performed, state-of-the-art, norm-compliant electrical connections are important to prevent accidents
and to ensure the screen's optimal and unaltered performance in time. Prior to carrying out any operation on electrical parts
ensure that power supply is disconnected. In screens fitted with cases the motor is positioned on the right hand side of the
screen as seen from the front (upon request it can be located on the left). Never connect two or more motors to the same
selector switch without a control unit or two switches to the same motor.
SCREENS WITH "MOTORISED INTEGRATED RADIO" ROLLER SYSTEM
ELECTRICAL CONNECTION: electric cabling must be conformant with applicable IEC standards. IEC norm EN 60335-1
requires that supply network be fitted with an omnipolar selector switch with contact opening distance of at least 3 mm.
Operates with standard radio control (supplied). Follow instructions provided in connection diagram on Fig. 5.
WARNING: Correctly performed, state-of-the-art, norm-compliant electrical connections are important to prevent accidents
and to ensure the screen's optimal and unaltered performance in time. Prior to carrying out any operation on electrical parts
ensure that power supply is disconnected. In screens fitted with cases the motor is positioned on the right hand side of the
screen as seen from the front (upon request it can be located on the left).
160
200
250
300
Kg 20
Kg 25
Kg 30
Kg 35
360
410
520
620
Kg 45
Kg 50
Kg 100
Kg 150

Publicité

loading