Make sure that the power cord and extension cable
are not damaged and in good condition.
•
Do not use the product if the power cord is
damaged. Let an approved service center repair the
product.
To do a check of the brush strip
•
Make sure that the brush strip is full.
•
Make sure that the brush strip touches the surface.
To do a check of the grind holder
CAUTION:
holder is important for the performance and
the safety.
1. Remove the tool plates (A).
A
The product does not start
•
Make sure that the power supply and the power
cords are not damaged.
•
Examine the emergency stop button, turn the button
clockwise to release the emergency stop.
•
Examine the overload lamp. If the overload lamp is
on, let the motor cool down for some minutes until
the product is automatically reset.
The product is not easy to hold on to
•
Too small number of diamond tools are installed on
the product.
•
The selected type of diamond tool is not correct for
the surface.
•
High current is used by the motor for the operation.
1146 - 003 - 21.03.2024
The condition of the grind
B
Troubleshooting
2. Examine the grind holders for damages and the
wear (B).
3. Replace or repair the grind holders if necessary.
•
Use the number of diamond tools that is
recommended to decrease the force on the product
and the operator. Refer to
10 .
The product has sudden movements
•
Make sure that all diamond tools are installed
correctly and that all have the same height.
The product stops after only a while
•
If the product overloads, the overload protection
engages and stops the motor.
•
Decrease the load. The lower hole is for a higher
handlebar and increased grind pressure. The top
hole is for a lower handlebar and decreased grind
pressure.
Diamond tools on page
15