The crown (L) lights completely, flashing, and a beep will be
heard: the control device of the charcoal filter is activated.
NB = to turn it off, turn off the hood, press the disk (T), L1 + L2
will be backlit, flashing; wait for the beep to confirm the
deactivation.
Grease filter saturation indicator
L1 + L2 flash when you have to perform maintenance of the
grease filter
Activated charcoal filter saturation indicator
L3 + L4 flash when you have to perform maintenance of the
activated charcoal filter
Reset of filter saturation signal
After filter maintenance, turn on the hood and press the disk
(T) for more than 5 seconds: you will hear a long tone (beep)
confirming the reset.
Note: In case of simultaneous signaling (grease filter and
activated charcoal filter saturation), you must repeat the reset
twice.
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend observing these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease filter -
Fig. 5-14
Traps cooking grease particles.
This must be cleaned at least once a month (or when the filter
saturation indication system - envisaged on the model in
possession - indicates this necessity), using non-aggressive
detergents, in a dishwasher, which must be set to a low
temperature and a short cycle (Tmax: 70°C).
When washed in a dishwasher, metal parts may discolour
slightly.
The filter must be dried in an oven for one hour at a max
temperature of 100°C; if the filter is still moist, repeat the
operation.
Replace the filter at least every 2 years.
To remove the grease filter, pull the spring release handle.
Charcoal filter (filter version only)
Fig. 13
It absorbs unpleasant odours caused by cooking.
The saturation of the charcoal filter occurs after more or less
prolonged use, depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least
every four mounths (or when the filter saturation indication
system – if envisaged on the model in possession – indicates
this necessity).The charcoal filter may NOT be washed or
regenerated.
Circular carbon filter
Apply one on each side as cover to both the shield grids of the
motor impeller, then turn clockwise.
For the disassembly, turn counter-clockwise.
Replacing lamps
The hood is equipped with a lighting system based on LED
technology.
The LEDs guarantee an optimum lighting, a duration up to 10
times as long as the traditional lamps and allow to save 90%
electrical energy.
For replacement, contact the technical service.
16