Possible incidents
The
pictogram is displaying
The
pictogram is still displaying
even though I have taken the corrective
actions above
The
pictogram is displaying
The
pictogram is flashing
The appliance cannot lower the level of
humidity to the desired value
The
pictogram is displaying
The
pictogram is displaying
Minimum duration of guarantee offered by the manufacturer: 2 years parts.
If your appliance does not seem to be working correctly, contact your EuroCave Professional retailer.
9/ TECHNICAL FEATURES AND ENERGY DATA
6000
Height
1
mm
1 temperature
6182V
1825
6074V
960
2
temperatures
6170D
1825
Multi-temperatures
6182S
1825
6074S
960
Control accuracy: +/- 1°C (2°F), display accuracy: +/- 1°C (2°F).
1Height including the top hinges and the feet, adjusted to mid-height.
Depth including a gap of 29mm at the back of the cabinet for ventilation.
2
According to delegated regulation (EU) 2019/2016 of the European Commission,
access energy data about our appliances on the EPREL database by scanning
the QR code visible on your appliance's energy label.
8/ OPERATING FAULTS
Causes
Corrective actions
The temperature has
Check that the door is correctly closed.
not returned to within
Check the condition of the door seal.
the ±4 °C threshold
If you placed a large amount of bottles in your cabinet in the last few hours,
wait a while then check again. If the alarm is still displaying, contact your
EuroCave Professional retailer.
Operating fault
Unplug the cabinet and contact your EuroCave Professional retailer.
Open door alarm
Make sure that the door is correctly closed.
The level of relative
• Pour a glass of water into the duct of the tray (see chapter 7, § IV).
humidity has been <
• In order to know how often to add water, count the number of days
50 % for over 72 hrs
separating the 1st day you added water and the day when the pictogram was
displayed
After a few hours, the pictogram will disappear.
• Empty the cabinet, remove the humidity cartridge and clean the tray.
• Remove the black drainage tube placed at the bottom of the cabinet.
Call the EuroCave Professional retailer if the problem persists despite having
carried out these different operations.
Charcoal filter alarm
Replace the charcoal filter (see chapter 4).
Temperature sensor
Contact the stockist / EuroCave customer service
fault alarm
Width
Depth
2
mm
mm
Full Glass door
680
715
680
715
680
715
680
715
680
715
The humidity will be directly discharged out of the appliance.
Weight when empty
Glass door (Kg)
Solid door (Kg)
(Kg)
96
94
60
58
100
98
94
92
58
56
The use of glass doors can alter your wine cabinet's performance
in some extreme temperature conditions.
Recommended
temperature range
Min T°(°C / °F) - Max T° (°C / °F)
Glass
Solid door
81
0-30 / 32-86
0-35 / 32-95
52
0-30 / 32-86
0-35 / 32-95
85
10-30 / 50-86
10-35 / 50-95
79
12-30 / 54-86
12-30 / 54-86
50
12-30 / 54-86
12-30 / 54-86
21