Precautions (Continued)
•
For single-temperature models only:
•
- If you notice low humidity levels (<55%) a few days after setting your
wine cabinet into operation, we recommend that you use the humidity
cartridge, supplied in a bag with the appliance. Place it at the bottom of
the cabinet, under the rack in the drip tray provided (see diagram below).
When using for the first time, completely immerse your cartridge in tap
water for a few minutes to saturate it then allow it to dry. Depending
on external conditions, it may be necessary to add a 10cl glass of water
after several months.
•
If the appliance is not able to
reduce humidity levels to the
desire value, remove the black
discharge pipe located at the base
of the cabinet
If you leave your wine cabinet closed for long periods (>3
months) in an environment where the temperature is close to your
cabinet's temperature setting
could create an environment in which mould develops or cause your
bottles's labels to peel off. Lack of dehumidification and air renewal
can create significant humidity inside the cabinet. We strongly
recommend that you regularly monitor your cabinet and clean it once
a year.
•
Install the stop (which is located in the accessories bag) at the back of
the cabinet (see diagram).
•
This allows a space of 7 cm
to be maintained between
the wall and the rear of the
cabinet. This spa
ce allows your cabinet's
power consumption to be
optimised.
•
Place the 2 caps in the 2
holes at the top of the
cabinet.
•
Do not push the caps all
the way in, in order to
allow the rear stop to be
installed.
•
Slide the rear stop between
the caps and the wall of the
cabinet, then push the 2
caps all the way in.
Installation
Place your cabinet in the desired location.
It must:
•
be open to the outside and well ventilated (not in an enclosed
cupboard, for example),
•
not be too damp. Max 85% ambient humidity (linen cupboard, laundry
room, bathroom...).
•
have a flat, stable floor,
•
be supplied with power (standard outlet, 16 A, earthed with 30mA*
circuit breaker). (* not applicable to some countries).
8
GB
4/ INSTALLING YOUR WINE CABINET
(a difference of about <5°C) this
•
Place your cabinet in the desired location.
•
Fit the charcoal filter (located in the "accessories" bag) by inserting it
into the breather hole located on the top left-hand side of the inside of
your cabinet (except 6170D model).
•
Take the lead and plug it into the connector, located at the back of the
cabinet, on the bottom left-hand side.
•
Wait 48hrs before plugging in
your cabinet
•
When using your cabinet for
the first time, the charcoal
filter alarm will display. Reset
the filter meter to 365 (see
chapter 6, § VII).
Fitting the handle
1. Full Glass door
•
Unscrew the three screws placed on the side of the door, using the Allen
wrench, which you will find in the handle's box.
•
Position the handle on the specially designed groove on the door frame
(figure 2).
•
Insert the handle all the way into the groove using a forward movement
(figure 2).
•
Screw the three screws back on (figure 3).
Fig.1
•
Take care not to catch the seal when screwing.
Note: adjustment of the handle is possible thanks to the oblong holes.
View from above
Handle
Front
Figure 1
Fig.2
Figure 2
Fig.3
2. Glass door with black frame and plain door
The handle can be found in its protective bag. It is attached to the rack at the
bottom of your cabinet.
•
Move the seal away from the handle position.
•
Screw the 2 screws using the Allen key (3 mm) provided in the bag of accessories.
•
Reposition the seal ensuring that it is correctly clipped in place.
Installation of two cabinets side by side
Caution: In the case of two side by side cabinets installed in extreme
conditions (Temperature >30°C - Relative Humidity > 70%), in order to
prevent condensation of stagnant air between the walls, please leave either
a minimum space of 5 cm between the two cabinets, or fill the space with
a foam sheet to remove the void.
Fig.1
Fig.2
Seal
Door frame
Fig.3
Figure 3