8. CONNECT WIRING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
Connect cables using provided wire connectors.
Connect wires as follow: WHITE to WHITES (A), BLACK WIRE WITH
YELLOW TAG from hood to BLACK wire from blower cord (B), two others
BLACK together (C) and GREEN or BARE wires under GREEN ground
screws (D).
DO NOT FORGET TO CONNECT THE GROUND.
9. REINSTALL SIDE PANELS
Reinstall both side panels, using 3 screws (removed from step 5) per side,
as shown beside.
Remove protective plastic film covering filters before
installing them.
Reinstall filters.