12. USE AND CARE
Grease filters and side panels.
The grease filters and the bottom panel should be cleaned frequently. Use a warm detergent solution.
Remove grease filters by pushing them towards the back of hood and rotating downward.
When cleaning the hood, never spray cleaning agent directly on the controls; spray it on the cleaning cloth and
wipe the control with it. Spraying cleaning agent directly on the control will cause unexpected keybord activation.
S
:
TAINLESS STEEL CLEANING
Do:
- Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe completely dry.
- You may also use a specialized household stainless steel cleaner.
Don't:
- Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
- Do not use any harsh or abrasive cleansers.
- Do not allow dirt to accumulate.
- Do not let plaster dust or any other construction residues reach the hood. During construction or renovation, cover
the hood to make sure no dust sticks to stainless steel surface.
Avoid: when choosing a detergent
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive
and should never be used close to a range.
P
:
AINTED FINISH
Clean with warm water and mild detergent only. If discoloration occurs, use a good enamel polish such as automotive
polish. (DO NOT use rough abrasive cleaner or porcelain cleaner).
13. WIRING DIAGRAM
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
Line 120 V
Supply
BK
BK
Neutral
W
W
Light Socket
50W max.
Ground
W
W
W
Light Socket
REMOTE BLOWER
WIRING COLOR CODE
BK
BLACK
W
WHITE
HE0044A
All manuals and user guides at all-guides.com
WARNING
!
BK
Y
BK
Y
50W max.
Note
3
W
BK
BK
W
3
1. If any of the original wire, as supplied, must be replaced, use the
Y
YELLOW
nc
no connection
2. Field wiring must comply with applicable codes, ordinances and
3. Marked black conductor, for blower wiring.
- 8 -
J5
3
nc
2
1
W
J6
3
Y
2
1
ELECTRONIC
ASSEMBLY
A1
Main power board
ELECTRONIC
ASSEMBLY
A2
User Interface
NOTES
same equivalent wire.
regulations.
J2
16
-t°
Heat Sentry

Publicité