• Unit measurements
• Assembly
Parts enclosed:
• 2 securing bra c ke ts (unit fixing)
• 1 strip sealing foam (white )
• 1 strip anti-v i b ration foam (black)
1 - Min. ceiling / conditioner space: 400 mm
2- Ceiling
3 - Cellar wa l l
4 - Anti-vibration and sealing foam
5 - Securing bra c ke ts
12
FRESH AIR
6 - Eva p o ra tor to be cleaned re g u l a rly (see p.1 4 )
7 - Condenser to be cleaned re g u l a rly (see p.1 4 )
8 - Inside of cellar
9 - Front panel
10 - Unit securing screws (not supplied)
1 1 - Front panel securing screw s
12 - Heating res i s to r
1 3 - Humidifier ta n k
1 4 - Wooden frame (optional)
a) Screw on the two securing brackets that you will find in the bag of
ironmongery (see diagram below)...
b) Place the self-adhesive anti-vibration foam along the bottom surface of the
opening (see previous drawing).
c) Without cutting, place sealing foam on the sides and top of the opening in
the wall, (half wall thickness).
d) Working from the outside of the cellar, introduce the conditioner into the
hole prepared in advance, until it comes into contact with the wall.
e) Secure the unit to the wall, using screws and rawl plugs suitable for the type
of material, and tighten (2 screws).
f) From inside the cellar, introduce insulation into the remaining space between
the conditioner and the opening. Warning, do not use a synthetic foam spray.
g) Leave the unit to settle for 24 hours before powering up.
h) Plug in the conditioner and check that the socket is earthed.
13