Télécharger Imprimer la page

Eurocave CL-C Guide D'utilisation page 11

Climatiseur de cave

Publicité

Les langues disponibles

Les langues disponibles

The default setting is 12 °C (ideal cellaring temperature). However, this
temperature can be set between 9 and 15°C. Outside this range the two keys
and
are disabled.
Display
Example:
before
Modification of the
resetting::
t e m p e ra t u re sett i n g
from 14°C to 12°C.
Step 1
Step 2
Step 3
Step 4
5
The Heating Function
The EuroCave CL-C cellar conditioner is equipped with a 500 W heating
element, which maintains the temperature inside your cellar.
As soon as the temperature falls below the set temperature, the heating function
is automatically triggered (the button
6
or
lights up).
6
Important safety recommendations
• When using the conditioner, always respect these few basic safety
precautions:
Only ever use the cellar conditioner for its intended purpose, as described in
this guide.
Never unplug the unit by pulling on the power lead. Hold the plug firmly and
pull it directly from the socket in a straight line. Never use a split lead or one
with signs of wear along the length. Always have any damaged lead replaced by
a qualified electrician.
Do not allow children to climb or hang on the cellar conditioner, they could
be seriously injured and damage the conditioner.
• The power supply (mains):
Important
FOR YOUR OWN SAFETY, THE CONDITIONER MUST BE CORRECTLY
EARTHED.
Your cellar conditioner's power lead comes without a plug.
You may fit a standard electrical plug or a qualified electrician
may make a hard-wired connection to a junction box.
Whatever the case, the unit must always be connected to an
earthed terminal in order to avoid any risk of electric shocks.
Have your mains socket tested by an electrician to make sure
that it is correctly earthed, and if necessary have it brought into conformity
with standards.
230V - 1 3A power socket with earth link, and circuit bre a ker with fuse pro tection.
IMPORTANT : Legislation requires that any intervention with the electrical
system or wiring is carried out by a qualified electrician.
• When your unit is delivered, the power lead is
located inside it.
• Remove the front cover by undoing the 4
securing screws.
• Remove the bag containing the 2 securing
brackets.
• Slide the lead through the raceway provided
(see drawing).
N.B. : Do not replace the cover before you have
c o r re c t ly
positioned
the
condensation
evacuation hose (section 7 p.8).
7

Publicité

loading