When using the machine under the aforemen-
tioned conditions, you must wear rubber gloves
and boots and use a ground circuit breaker.
• Keep the generator clean and free from oil, dirt and
other foreign particles.
• Ensure that extension cables, power cables and all
electrical components are in a flawless condition.
Never operate electrical devices with damaged or
faulty cables.
• To prevent burning, do not touch the exhaust and
other motor and generator parts that heat up dur-
ing operation.
• Do not connect the machine to domestic power
outlets.
• Do not connect it to other electricity sources.
Do not use the generator under the following con-
ditions:
• when changing the motor speed
• when the electrical power decreases
• when a misfire occurs
• when sparks form
• during excessive vibration
• when flames or smoke appear
• in closed rooms
• during rain or rough weather
• in closed room sections
• when connected devices overheat
• in the event of damage to the sockets
Regularly check the fuel system for leakages and
traces of wear and tear such as abraded or porous
lines, loose or missing brackets and damage to the
tank or tank lid. All faults must be resolved before
use.
The generator should be used, maintained and refu-
elled only under the following conditions:
• Sufficient ventilation. Avoid environments in which
fumes can accumulate, such as ditches, base-
ments, excavations and bilges. Observe the air
flow and temperature. The ambient temperature
should not exceed 40°C.
• In closed rooms, disperse hazardous fumes via
pipes. The motor fumes contain carbon monox-
ide, a toxic, odourless and colourless gas, which
causes severe health damage and possibly death,
when inhaled.
• Refuel the generator only when there is sufficient
lighting. Avoid spilling fuel. Never refuel the gen-
erator during operation. Leave the motor to cool
down for about two minutes before refuelling.
• Do not carry out refuelling close to open fires, in-
dicator lights or sparking electrical devices such
as power tools, welding machines or grinding ma-
chines.
• Check sound absorbers and air filters for flawless
condition. These parts act as flame protection in
the event of misfire.
20 | GB
• Do not smoke close to the generator. Do not wear
loose clothing, jewellery or similar objects that may
get caught by the starter motor or other rotary parts.
Dangers and protective measures
Exhaust gases:
Inhalation of exhaust gases
Only use the unit outdoors
Electric shock:
Touching the spark plug - Do not touch the spark
plug connectors when the engine is running
Burns:
Touching the exhaust - Allow the unit to cool
Fire - explosion:
Petrol is inflammable - Smoking is prohibited when
refuelling and working
m WARNING! This electric tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain con-
ditions. In order to prevent the risk of serious or deadly
injuries, we recommend that persons with medical im-
plants consult with their physician and the manufactur-
er of the medical implant prior to operating the electric
tool.
6. Technical data
IP class
Continous power P
Maximum power P
5 min)
Rated voltage U
Rated current I
Frequency F
Drive engine design
Displacement
Maximum power (motor)
Fuel
Tank capacity
Type of motor oil
Amount of oil (approx.)
Consumption at 2/3 load
Weight
Performance class
Temperature max
Max. altitude
Starter motor
www.scheppach.com
(S1)
nenn
(S2
max
2 x 230 V~
12 V / 8,3A
nenn
nenn
nenn
4 stroke 1 cylinder air
4,8 kW / 6,5 HP
unleaded fuel
10W30 / 15W40
reversing starter
IP23M
2500 W
2800 W
16 A
50 Hz
colled
196 cm
3
15 l
0,6 l
1,39 l/h
43 kg
G2
40
C
°
1000 m