Télécharger Imprimer la page

mspa OSLO F-OS063W Guide Du Propriétaire page 12

Masquer les pouces Voir aussi pour OSLO F-OS063W:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

NOTE: Always keep the spa cover on to minimize heat loss when heating the water.
Make sure the cover, and mostly its side facing water, will not come into contact with the ground or any other dirt when
not in use.
Covers shall be cleaned inside and out periodically using a suitable solution that includes adequate disinfection (e.g.
10ml/l of free Chlorine).
Your spa is equipped with a 2200W PTC heater. To guarantee you a best spa experience, it will intelligently allocates
the power according to different function being activated.
FILTRATION
FILTER button to turn the function on/off. The button lights up when function is activated.
Press the
NOTE: The filtration system will automatically start when the heating, Ozone or UVC sanitizing system is activated.
NOTE: After turning off the heating system, the filtration system will automatically stop in 30 seconds.
Filter Cartridge Cleaning Reminder: When the FILTER icon flashes continuously, the filter cartridge must be cleaned
or replaced. Once this has been done, press the Filter button for 3 seconds to reset the reminder.
Auto-filtration: When the spa is in stand-by mode, the filtration system will operate automatically for 60 minutes every
8 hours.When the ambient temperature is below 1°C / 33.8°F, the filter will run automatically to prevent the tube from
freezing.
BUBBLE MASSAGE
Press the
BUBBLE button to turn the function on; hold down the BUBBLE button for 3 seconds to turn the function
off. The BUBBLE button lights up when function is activated.
The bubble setting can be adjusted to three different levels. The default setting is at level 3
BUBBLE button to switch the setting to level 1
IMPORTANT: Do not turn on the massage system when the cover is attached. Air can accumulate inside the spa and
cause irreparable damage and bodily harm.
NOTE: The bubbling massage function will shut down automatically after every 20 minutes of operation as a safety
precaution. This can be reactivated after 10 minutes by pressing the BUBBLE button again.
HEATING TIMER
To set the number of hours FROM NOW when the heater will activate:
1. Press the
TIMER button to enter pre-setting mode. The button lights up.
1-99h
2. Pressing the
of hours before heater activation (from 1 to 99 hours). The desired timer setting will remain on the LED display for 3
seconds to confirm the value.
To modify the timer setting: Press the Timer button again and use the UP or the DOWN button to adjust.
Cancel the setting: Press the TIMER button for 3 seconds.
NOTE: Activating the heating system or rebooting the spa will cancel the timer setting.
UVC SANITIZER
Press the
UVC button to turn the UVC sanitizing system on/off. When the button lights up, the UVC sanitizing
system is activated.
NOTE: The UVC emitter is built inside the control box. Therefore, the function can be turned on at any time, even with
people inside the spa.
OZONE
Press the
OZONE button to turn the function on/off. The button lights up when the function is activated. The
Ozonator will shut down automatically after operating for 2 hours.
NOTE: For your own safety, do not bathe in the spa when the OZONE function is turned on. The OZONE function
cannot be turned on when the JET or BUBBLE function is on. We suggest turning on the function after using the spa.
UP or
DOWN button will cause the LED to flash. While it is flashing, you can adjust the number
Lock
(300W). Press it again to switch to level 2
12
Unlock
(720W). Press the
(500W).

Publicité

loading