3.4 Chimneys and flue pipes
• The fireplace can be connected to a chimney and flue
pipe approved for solid fuel fired appliances with flue gas
temperatures specified in «2.0 Technical data».
• The chimney's cross-section must be at least as big as the
flue pipe's cross-section. See «2.0 Technical data» when
calculating the correct chimney cross-section.
• Several solid fuel fired appliances can be connected to the
same chimney if the chimney's cross-section is sufficient.
• Connection to the chimney must be carried out in accordance
with the installation instructions from the supplier of the
chimney.
• Before making a hole in the chimney the fireplace should be
test-mounted in order to correctly mark the position of the
fireplace and the hole in the chimney. See fig. 1 for minimum
dimensions.
• Ensure that the flue pipe is inclined all the way up to the
chimney.
• Use a flue pipe bend with a sweeping hatch that allows it to
be swept.
Be aware of the fact that it is particularly important that
connections have a certain flexibility in order to prevent
movement in the installation leading to cracks.
N.B. A correct and sealed connection is very important for the
proper functioning of the product.
Chimney draught; See «2.0 Technical data». If the draught is
too strong you can install and operate a flue damper to control
the draught.
3.5 Assembly prior to installation
The product is delivered in a single packing case.
After unpacking the stove check that the stove is free of any
damage and that the regulating handles works.
NB! The adjusting screws on the inside of the bases (fig. 8) can be
used to level the stove if the floor is unlevelled.
Minimum chimney cross section is recommended to be 177 cm
(corresponding to 150 mm dia.) See fig. 3.
3.6 Control of functions (fig. 2)
When the product is set up, always check the control functions.
These shall move easily and function satisfactorily.
Jøtul F 250 is equipped with the following controls:
Air vent control.
fig. 2A
Ignition vent control
Fig. 2B
Left position
= Closed
Right position = Fully open
3.7 Ash removal
Jøtul F 250 has an ash pan which makes it easy to remove the ash.
1. Scrape the ash through the grate in the base plate and into
the ash pan. Use something like a glove to grab the handle
on the ash pan.
2. Make sure that the ash pan doesn't fill up so high that it keeps
ash from coming through the grate into the pan.
3. Make sure the door to the ash pan is securely shut when the
stove is in use.
For the rest, see description of how to handle ash in the Manual
on general use and maintenance in Point «6.1 Fire preventive
measures».
4.0 Service
Warning! Any unauthorised change to the product is illegal.
Only use original spare parts.
4.1 Changing the burn plates/inner
bottom plate (fig. 5-6)
• Remove the baffle plate (fig. 6)
• Remove the side burn plates (5A) by lifting them up a little
and then out. (Be aware if using tools, that vermiculite plates
may be damaged by rough handling).
• Unscrew the screws at the back of the rear burn plate (B) and
remove the burn plate.
• Then lift up and remove the inner bottom plate (C).
Follow the same procedure for installation, but in the opposite
sequence.
4.2 Changing the baffle plate (fig. 6-7)
• Lift the baffle plate (fig. 6) and remove it through the door.
Access is then easy to baffle plate II (fig.7) if this needs to be
removed. This is situated on 1 knob in the back (A) and 2 knobs
in the front (B).
• Edge it down and remove it through the door.
For re-installation follow the same procedure in the opposite
sequence.
5.0 Optional equipment
Soap stone panels- cat. no. 350922
Assembly instructions are included with the product.
2
Aluminiumpanels- cat. no. 350923
Assembly instructions are included with the product.