The power supply units generally have to be mounted outside the hazardous endangered areas. The
sensor has an LED visible from outside, which displays the operating state.
For KAS only: The sensitivity adjustment is made by means of a potentiometer or EasyTeach wire ac-
cessible from outside.
Certificates and markings
Version
Certificate no.
Europe (ATEX)
DMT 01 ATEX E 157 Ex II 2G Ex mb IIC T4 Gb Ex II 1/2 D Ex ta/tb IIIC T101°C Da/Db
Applied standards: EN IEC 60079-0:2018, EN 60079-18:2015+A1:2017, EN 60079-31:2014
Global (IECEx)
IECEx BVS 07.0015 Ex mb IIC T4 Gb
Applied standards: IEC 60079-0:2017, IEC 60079-18:2017, EN 60079-31:2013
China (CCC)
2020312315000410 Ex mb IIC T4 Gb
Applied standards: GB/T3836.1-2021, GB/T3836.9-2021, GB/T3836.31-2021
Conformity to standards and regulations
Certificates and EU declaration of conformity, see www.rechner-sensors.com.
The devices have an IECEx approval. Certificate see IECEx homepage: http://iecex.iec.ch/
Further national and international certificates are available for download at the following link:
www.rechner-sensors.com.
Thermal and electrical data
Appliance-group II category
1/2D Ex ta/tb IIIC T101°C Da/Db
Permitted ambient temperature: -20...+90 °C
Electrical data:
Operating voltage:
Operating current value:
Degree of protection:
Potential compensation:
Sensors with a metal housing have a cable connection with a protective conductor (yellow-green). This is
an internal galvanic connection to the metal housing. The protective wire must be connected.
Please note: The conditions of the EN 60079-26:2007 e. g. relating to dust-coating and temperatures
must be met.
The sensor must not be powered when making the initial connection! Wrong connection can
destroy the sensor!
+ = Brown
Output 1 = Black
The sensor has an internal high-speed fuse of 200 mA. It is not possible to replace the
fuse. An external back-up high-speed fuse of 100 mA can be connected for protection of
the sensor.
Maintenance, repair, disposal
• Maintenance for this device is not necessary when used as intended.
• It is not possible to repair the device. If you have any problems, please contact directly your customer
service.
• Please dispose of the device in a way that is environmentally friendly according to the national
regulations.
Group II category gas
10...30 V DC
up to 200 mA
IP 67
- = Blue
Green/yellow =
Output 2 = White
Group II category dust
Ex ta/tb IIIC T
Ex ta/tb IIIC T
Appliance-group II category
2G Ex mb IIC T4 Gb
Electrical data:
Operating voltage:
Operating current value:
Degree of protection:
101°C Da/Db
200
101°C Da/Db
200
10...30 V DC
up to 200 mA
IP 67